BL672D Dual Blackbody Calibration Source
BL672D Dual Blackbody Calibration Source
The BL672D is a benchtop blackbody calibration source utilizing a digital indicating temperature ambient 30℃ to 50℃ (86F to 122F). Two 60mm diameter end closed tubes are heated or cooled with an internal solid-state thermoelectric heat pump. It has a built-in digital temperature controller to provide accurate, stable temperature as well as to provides readout. |
FEATURE
- 0.99 emissivity
- Two end closed tubes with 60mm diameter
- 0.05℃high stability
- Calibrate from 30℃ to 50℃
- Quickly heat up to 50℃in 10 minutes
- Built-in temperature correction function
- Quick and easy operate
Application
- Calibrate thermal camera
- Calibrate infrared thermometer
Specification
Temperature Range |
30℃ to 50℃ (86F to 122F) |
Aperture size |
60 mm diameter |
Emissivity |
> 0.99 |
Display accuracy |
± 0.05℃ |
Display resolution |
0.01℃ |
Control stability |
± 0.05℃ after 10 minutes |
Blackbody uniformity |
± 0.05℃ |
Heat cavity shape |
Two end closed tube |
Heat up time |
10 minute from ambient to 50℃ |
Control method |
Digital PID controller with readout |
Temperature sensor |
Precision platinum RTD |
Power supply |
110-220V AC, 50Hz, 60W |
Interface |
RS232 |
Dimension |
435 mm(D) x 290 mm(W) x 200mm(H) |
Net weight |
Appr. 10 kg |
Scope of delivery
· BL672D Dual blackbody calibration source with carrying case · Power adapter as standard 110-240V AC · Factory test report |
Optional Accessories
USB into RS232 adapter (P/N:1622) Accredited calibration certificate (P/N: 9000-672D) |
Image gallery
|
|
|
|
BL672S Isothermal Blackbody Calibration Source
BL672S Isothermal Blackbody Calibration Source
With isothermal cavity, the BL672S is a portable blackbody calibration source utilizing a digital indicating temperature ambient 20℃ to 50℃ (68F to 122F). The 80 mm diameter end closed tube is heated or cooled with an internal solid-state thermoelectric heat pump. It has a built-in digital temperature controller to provide accurate, stable temperature as well as to provide readout. |
FEATURE
- The isothermal cavity
- Better than 0.995 emissivity
- 80mm diameter aperture
- 0.05°C high stability
- Calibrate from 20°C to 50°C
- Built-in temperature correction function
- Portable and easy operate.
Application
- Calibrate ear infrared thermometer
- Calibrate forehead infrared thermometer
- Calibrate thermal camera
- Calibrate infrared screening instrument
- Calibrate infrared sensor
Specification
Temperature Range |
20℃ to 50℃ (68F to 122F) |
Aperture size |
80 mm diameter |
Emissivity |
> 0.995 |
Cavity type |
Isothermal Cavity |
Display resolution |
0.01℃ |
Control stability |
± 0.05℃ after 10 minutes |
Blackbody uniformity |
± 0.05℃ |
Heat cavity shape |
End closed tube |
Heat up time |
10 min. from amb. to 20℃, 10 min. from amb. to 50℃ |
Control method |
Digital PID controller with readout |
Temperature sensor |
AAA Precison platinum RTD |
Power supply |
110-220V AC, 50Hz, 350W |
Interface |
RS232 |
Dimension |
320 mm(D) x 195 mm(W) x 275mm(H) |
Net weight |
Appr. 6 kg |
Scope of delivery
· BL672S Isothermal blackbody calibration source with carrying case · Power adapter as standard 110-240V AC · Factory test report |
Optional Accessories
USB into RS232 adapter (P/N:1622) Accredited calibration certificate (P/N: 9000-672S) |
Image gallery
|
|
|
|
BL502 Pneumatic Dead weight Tester
BL502 Pneumatic Deadweight Tester
The model BL502 pneumatic deadweight tester is ideal primary standard for defining the pressure scale in pneumatic range from 5kPa to 10MPa. The piston cylinder assembly is the heart of the dead weight tester and responsible for its high accuracy. We manufacture piston cylinder with accuracies from 0.05% up to 0.005% of reading. |
Overview
|
Application
- Primary pressure standard in lab
- Reference pressure measure in workshop
Specification
- Accuracy: 0.05%rdg, 0.02%rdg, 0.01%rdg, 50ppm (option)
- Piston and cylinder material: Tungsten Carbide
- Mass material: Forged 316 Stainless Steel
- Hydraulic base material: Aluminium
- Seal material: Buna-N, PTFE, Cu Alloy
- Medium: Dry air (<700kPa), Pure nitrogen (>700kPa)
- Gravity: Standard 9.80665 m/s², or customize local gravity.
- Pressure units available: MPa, bar, psi (optional)
- Pressure connector: Metric, (NPT and BSP is optional)
- Base dimension: 185 mm (H) x 455 mm (L) x 380 mm (D)
- Base weight: Appro.15kg
Pressure Selectable Sheet
P/N |
Pressure Range |
Kn Value |
Effective Area |
Mass Set |
KQ250 |
(5~250) kPa |
20kPa/kg |
5 cm2 |
12.5kg |
KQ400 |
(5~400) kPa |
20kPa/kg |
5 cm2 |
20kg |
KQ600 |
(10~600) kPa |
20kPa/kg |
5 cm2 |
30kg |
KQ1M |
(20~1000) kPa |
20kPa/kg |
5 cm2 |
50kg |
KQ1.6M |
(30~1600) kPa |
50kPa/kg |
2 cm2 |
32kg |
KQ2.5M |
(40~2500) kPa |
10.1MPa/kg |
5 cm2 |
25kg |
KQ4M |
(0.1~4) MPa |
0.2MPa/kg |
0.5 cm2 |
20kg |
KQ6M |
(0.1~6) MPa |
0.2MPa/kg |
0.5 cm2 |
30kg |
KQ10M |
(0.2~10) MPa |
0.2MPa/kg |
0.5 cm2 |
50kg |
Ordering info and accessories
Scope of delivery
|
Optional Accessories
|
Image gallery
|
|
|
BL506 Vacuum Dead weight Tester
BL506 Vacuum Dead weight Tester
|
With 0.01%rdg accuracy, the BL506 vacuum deadweight tester have dual vacuum and pressure modes. Pressure and vacuum application can be operated by hand pump or external gas supply. To guarantee an excellent metrology-logic characteristic, all pistons and cylinders are made of tungsten carbide. Because of the extreme hardness of this material, the pressure distortion (expansion) coefficient is negligible. The low friction coefficient provides minutes of turning with just a little swing of the masses. |
Overview
|
Application
- Primary pressure standard in lab
- Reference vacuum measure in workshop
Specification
- Accuracy: 0.01%rdg, 0.02%rdg, 0.005%rdg (customized)
- Piston and cylinder material: Tungsten carbide
- Mass material: Forged 316 stainless steel
- Tester base and pump material: Aluminium
- Seal material: Buna-N, FTM PTFE, Cu Alloy
- Medium: Dry and clean air
- Pressure units available: MPa, bar, psi (optional)
- Pressure connector: Metric, (NPT and BSP is optional)
- Gravity: Standard 9.80665 m/s², or customize local gravity.
- Tester dimension: 500 mm (H) x 650 mm (L) x 500 mm (D)
- Pump dimension: 225 mm (H) x 455 mm (L) x 380 mm (D)
- Tester weight: Appro.25kg / Pump weight: Appro.15kg
- Warranty: two years
Pressure Selectable Sheet
P/N |
Pressure Range |
Kn Value |
Effective Area |
Mass Set |
KYQZ100 |
(-0.1~0.1) MPa |
10kPa/kg |
10 cm2 |
10kg+10 kg |
KYQZ160 |
(-0.1~0.16) MPa |
20kPa/kg |
5 cm2 |
5 kg+8kg |
KYQZ250 |
(-0.1~0.25) MPa |
20kPa/kg |
5 cm2 |
5 kg+12.5kg |
KYQZ400 |
(-0.1~0.4) MPa |
20kPa/kg |
5 cm2 |
5 kg + 20kg |
KYQZ600 |
(-0.1~0.6) MPa |
20kPa/kg |
5 cm2 |
5 kg + 30kg |
Ordering info and accessories
Scope of delivery
|
Optional Accessories
|
Image gallery
|
|
|
BL507 Low Pressure Dead weight Tester
BL507 Low Pressure Dead Weight Tester
The model BL507 low pressure deadweight tester is ideal primary standard for defining the pressure scale in pneumatic range from 1.2kPa to 40kPa. The special design for piston model can ensure accuracy up to 0.01% of reading. |
Overview
|
Application
- Primary pressure standard in lab
- Reference pressure measure in workshop
Specification
Model |
BL507 |
Accuracy |
0.02%rdg / 0.01%rdg |
Resolution |
10Pa / 0.1mbar / 0.04inch water |
Piston material |
316 stainless steel |
Cylinder material |
Tungsten carbide |
Mass material |
Forged 316 stainless steel |
Hydraulic base material |
Aluminium |
Seal material |
Buna-N |
Medium |
Dry air |
Gravity |
Standard 9.80665 m/s² or customize local gravity |
Pressure units |
kPa, mbar, inch water (optinal) |
Pressure connector |
NPT and BSP is optional |
Base dimension |
185mm (H) x 455mm (L) x 380mm (D) |
Base weight |
Appr.10kg |
Warranty |
2 years |
Pressure Range Selectable Sheet
Part Number |
KYQ10 |
KYQ16 |
KYQ25 |
KYQ40 |
Pressure Range |
(1.2~10) kPa |
(1.2~16) kPa |
(1.2~25) kPa |
(1.2~40) kPa |
Kn Value |
10kPa/kg |
10kPa/kg |
10kPa/kg |
10kPa/kg |
Effective Area |
10 cm2 |
10 cm2 |
10 cm2 |
10 cm2 |
Mass Set |
1 kg |
1.6 kg |
2.5 kg |
4 kg |
Ordering info and accessories
Scope of delivery
|
Optional Accessories
|
Image gallery
|
|
|
BL508 Differential Pressure Dead Weight Tester
BL508 Differential Pressure Deadweight Tester
|
The model BL508 high static differential pressure deadweight tester ideal primary standard for defining the static pressure up to 60MPa. Both the piston and cylinder are manufactured from tungsten carbide. This pairing of materials, in comparison to other materials, has very low pressure and temperature coefficients of expansion, which results in a very good linearity for the effective area of the piston and a very high accuracy. Over-pressure protection is integrated, which prevents the piston from being forced out vertically and avoids damage to the piston-cylinder system in the event of masses removal under pressure. |
Overview
|
Application
- Primary pressure standards in laboratories
- Precision pressure measurement
Specification
Model |
BL508 |
Accuracy |
When use one of two piston gauges, accuracy is 0.01%rdg; When test static pressure, accuracy is (2Pa + 5x10-7*P + 1x10-4*△P), where P= Static Pressure Pa, △P = differential pressure value |
Piston material |
Tungsten carbide |
Cylinder material |
Tungsten carbide |
Mass material |
Forged 316 stainless steel |
Hydraulic base material |
Casting iron |
Seal material |
Buna-N, FTM, PTFE, Copper Alloy |
Medium |
Mineral oil lubricated and pure nitrogen operated (built in oil-gas separator) |
Gravity |
Standard 9.80665 m/s² or customize local gravity |
Pressure units |
MPa, bar, psi (optional) |
Pressure connector |
Metric, (NPT and BSP is optional) |
Base dimension |
540 mm (H) x 625 mm (L) x 480 mm (D) |
Base weight |
Appr.35kg |
Warranty |
2 years |
PRESSURE SELECTABLE SHEET
Part Number |
Pressure Range |
Kn Value |
Effective Area |
Piston & Cylinder |
Increment Mass Set |
Media |
GCY7 |
(0.1~7) MPa |
0.5MPa/kg |
0.2 cm2 |
200g |
14kg+14kg |
N2 |
GCY20 |
(0.5~20) MPa |
1MPa/kg |
0.1 cm2 |
500g |
20kg+20kg |
N2 |
GCY60 |
(1~60) MPa |
2MPa/kg |
0.05cm2 |
500g |
30kg+30kg |
N2 |
Ordering info and accessories
Scope of delivery
|
Optional Accessories
|
Image gallery
|
|
|
BL510 Portable Pressure Dead weight Tester
BL510 Portable Pressure Dead weight Tester
|
The model BL510 portable deadweight tester provide a precise means for generating pressure with high accuracy that can be used as a primary calibration standard. The unit's built-in shuttle valve provides the means to control the rate of pressure increase, while precision adjustment is accomplished with an integral micro vernier displacement valve. An ideal product that offers a rugged field ready primary standard, certified to yield consistent accurate results |
Overview
|
Application
- Primary pressure standards in laboratories
- Precision pressure measurement
Specification
Model |
BL510 |
Accuracy |
±0.05% of reading |
Range pressure |
15 psi to 15,000 psi |
Piston material |
Tungsten carbide |
Cylinder material |
Tungsten carbide |
Mass material |
Carbon steel |
Certificate |
CNSA calibration traceable |
Seal material |
Buna-N |
Fluid |
Sebacate (≥25MPa) |
Gravity |
Standard 9.80665 m/s² or customize local gravity |
Pressure units |
MPa, bar, psi, kg/cm2 |
Working ambient temperature |
15~25℃ |
Base dimension |
300 x 320 x 260 mm |
Tester net weight |
Appr.12kg |
Warranty |
2 years |
PRESSURE SELECTTABLE SHEET
P/N |
Pressure Range |
Kn |
Effective Area |
Mass Set |
KY0 |
(0.04~0.6) MPa |
0.1MPa/kg |
1cm2 |
6kg |
KY1 |
(0.04~1) MPa |
0.1MPa /kg |
1cm2 |
10kg |
KY6 |
(0.1~6) MPa |
0.5MPa /kg |
0.2 cm2 |
12kg |
KY25 |
(0.5~25) MPa |
1MPa /kg |
0.1 cm2 |
25kg |
KY60 |
(1~60) MPa |
2MPa/kg |
0.05 cm2 |
30kg |
KY70 |
(1~70) MPa |
2MPa/kg |
0.05 cm2 |
35kg |
KY100 |
(1~100) MPa |
2MPa/kg |
0.05 cm2 |
50kg |
KY160 |
(2~160) MPa |
2MPa/kg |
0.05 cm2 |
80kg |
KY250 |
(5~250) MPa |
5MPa/kg |
0.02 cm2 |
50kg |
Ordering info and accessories
Scope of delivery
|
Optional Accessories
|
Image gallery
|
|
|
BL511 Hydraulic Pressure Dead weight Tester
BL511 Hydraulic Pressure Deadweight Tester
|
With 0.01% of reading accuracy, pressure ranges from 40kPa to 250MPa, the model BL511 hydraulic deadweight testers are applicable in very wide variety of pressure calibration and measurement tasks. The piston cylinder assembly is the heart of the dead weight tester and responsible for its high accuracy. We manufacture piston cylinder with accuracies from 0.05% up to 0.005% of reading. To give an idea of the manufacturing skills, the space between the piston and the cylinder is in the um range and can only be measured in a climate room. |
Overview
|
Application
- Primary pressure standards in laboratories
- Reference instruments on the workshop.
Specification
Model |
BL511 |
Accuracy |
0.01%rdg, 0.02%RD, 0.05%RD |
Piston material |
Tungsten carbide |
Cylinder material |
Tungsten carbide |
Mass material |
Forged 316 stainless steel |
Hydraulic base material |
Aluminium |
Seal material |
Buna-N, FTM, PTFE, Cu Alloy |
Fluid |
Mineral Oil(<25MPa); Sebacate (≥25MPa) |
Gravity |
Standard 9.80665 m/s² or customize local gravity |
Pressure units |
MPa, bar, psi (optional) |
Connector |
Metric, (NPT and BSP is optional) |
Base dimension |
225 mm (H) x 455 mm (L) x 380 mm (D) |
Tester net weight |
Appr.18kg |
Warranty |
2 years |
Pressure Selectable Sheet
P/N |
Pressure Range |
Kn |
Effective Area |
Mass Set |
KY0 |
(0.04~0.6) MPa |
0.1MPa/kg |
1cm2 |
6kg |
KY1 |
(0.04~1) MPa |
0.1MPa /kg |
1cm2 |
10kg |
KY6 |
(0.1~6) MPa |
0.5MPa /kg |
0.2 cm2 |
12kg |
KY25 |
(0.5~25) MPa |
1MPa /kg |
0.1 cm2 |
25kg |
KY60 |
(1~60) MPa |
2MPa/kg |
0.05 cm2 |
30kg |
KY70 |
(1~70) MPa |
2MPa/kg |
0.05 cm2 |
35kg |
KY100 |
(1~100) MPa |
2MPa/kg |
0.05 cm2 |
50kg |
KY160 |
(2~160) MPa |
2MPa/kg |
0.05 cm2 |
80kg |
KY250 |
(5~250) MPa |
5MPa/kg |
0.02 cm2 |
50kg |
Ordering info and accessories
Scope of delivery
|
Optional Accessories
|
Image gallery
|
|
|
BL513 Water Pressure Dead weight Tester
BL513 Water Pressure Dead weight Tester
|
The model BL513 water deadweight testers are applicable oil-free pressure calibration and measurement solution. The oil-free test performance of BL513 is much better than other solution of hydraulic piston gauges plus oil-water separator. The piston and cylinder is the technical heart of deadweight tester. Our experience and knowledge of piston/cylinder production and calibration ensure the precision and performance required for wide demanding calibration requirements. |
Overview
|
Application
- Primary pressure standard for oil-free gauge
- Reference instruments in field.
Specification
Model |
BL513 |
Accuracy |
0.05%rdg, 0.01%rdg, 0.02%rdg, (Increased accuracy option of 0.005%rdg |
Piston material |
Tungsten carbide |
Cylinder material |
Tungsten carbide |
Mass material |
Forged 316 stainless steel |
Hydraulic base material |
Stainless Steel |
Seal material |
Buna-N, FTM, PTFE, Cu Alloy |
Fluid |
Pure distilled water |
Gravity |
Standard 9.80665 m/s² or customize local gravity |
Pressure units |
MPa, bar, psi (optional) |
Connector |
Metric, (NPT and BSP is optional) |
Base dimension |
225 mm (H) x 455 mm (L) x 380 mm (D) |
Tester net weight |
Appr.20kg |
Warranty |
2 years |
PRESSURE SELECTABLE SHEET:
Part Number |
KYS25 |
KYS60 |
KYS70 |
KYS100 |
Pressure Range |
(0.5~25) MPa |
(1~60)MPa |
(1~70)MPa |
(1~100)MPa |
Kn |
1 MPa/kg |
2 MPa/kg |
2 MPa/kg |
2 MPa/kg |
Effective Area |
0.1 cm2 |
0.05 cm2 |
0.05 cm2 |
0.05 cm2 |
Mass Set |
25kg |
30kg |
35kg |
50kg |
Ordering info and accessories
Scope of delivery
|
Optional Accessories
|
Image gallery
|
|
|
BL516 Hydraulic Pressure Balance
BL516 Hydraulic Pressure Balance
|
The model BL516 Hydraulic Pressure Balances are widely applicable in primary pressure calibration laboratory. Both the piston and cylinder are manufactured from tungsten carbide. This pairing of materials, in comparison to other materials, has very low pressure and temperature coefficients of expansion, which results in a very good linearity for the effective area of the piston and a very high accuracy. Over-pressure protection is integrated, which prevents the piston from being forced out vertically and avoids damage to the piston-cylinder system in the event of masses removal under pressure. |
Overview
|
Application
- Primary pressure calibration in lab
- Precision pressure measurement
Specification
Model |
BL516 |
Accuracy |
0.005%RD |
Piston material |
Tungsten carbide |
Cylinder material |
Tungsten carbide |
Mass material |
Forged 316 stainless steel |
Hydraulic base material |
Casting iron |
Seal material |
Buna-N, FTM, PTFE, Cu Alloy |
Fluid |
Mineral Oil (<25MPa); Sebacate (≥25MPa) |
Gravity |
Standard 9.80665 m/s² or customize local gravity |
Pressure units |
MPa, bar, psi (optional) |
Connector |
Metric, (NPT and BSP is optional) |
Base dimension |
410 mm (H) x 375 mm (L) x 445 mm (D) |
Tester net weight |
Appr.32kg |
Warranty |
2 years |
Pressure Selectable Sheet
P/N |
Pressure Range |
Kn |
Effective Area |
Mass Set |
KY0.6 |
(0.04~0.6) MPa |
0.1MPa/kg |
1cm2 |
6kg |
KY6 |
(0.1~6) MPa |
0.5MPa /kg |
0.2 cm2 |
12kg |
KY25 |
(0.5~25) MPa |
1MPa /kg |
0.1 cm2 |
25kg |
KY60 |
(1~60) MPa |
2MPa/kg |
0.05 cm2 |
30kg |
KY70 |
(1~70) MPa |
2MPa/kg |
0.05 cm2 |
35kg |
KY100 |
(1~100) MPa |
2MPa/kg |
0.05 cm2 |
50kg |
KY160 |
(2~160) MPa |
2MPa/kg |
0.05 cm2 |
80kg |
KY250 |
(5~250) MPa |
5MPa/kg |
0.02 cm2 |
50kg |
Ordering info and accessories
Scope of delivery
|
Optional Accessories
|
Image gallery
|
|
|
Baluntech BL676 Portable Infrared Calibration Source
BL676 Portable Infrared Calibration Source
|
Temperature range 50℃ to 500℃ Emissivity is better than 0.995 Temperature uniformity is up to 0.15℃ 50 mm aperture diameter end close tube emitter Built-in temperature correction function Light weight, easy to carry Robust construction |
Overview
The BL676 is a portable blackbody calibration source utilizing a digital indicating temperature ambient 50 to 500℃ (122F to 932F). A precision platinum RTD temperature sensor is embedded in the blackbody emitter, providing high accuracy and repeatability. The temperature controller uses the industry standard PID algorithms to control the emitter temperature to within 0.1℃ of the set points. The black body emitter mechanism uses a resistive heating device that provides a long life, short stabilization times, and stable temperature control. |
Applications
- Infrared temperature sensors
- Infrared thermal imaging systems
- Spectrographic analysers
- Radio meters
- Flux meter
Specifications
Temperature Range |
50℃ to 500℃ (122F to 932F) |
Aperture diameter |
50 mm |
Emissivity |
> 0.995 |
Display resolution |
0.1℃ |
Control stability (10 min) |
±0.1℃ or 0.1%t (whichever is greater) |
Blackbody uniformity |
0.15℃ or 0.15%t (whichever is greater) |
Heat cavity shape |
End closed tube |
Control method |
Digital PID controller with readout |
Temperature sensor |
Precision Platinum RTD |
Power supply |
220V AC, 500 WA |
Interface |
RS232 |
Heat up time |
less than 1 hour from ambient to 500℃ |
Calibration method |
Pyrometric standard calibration |
Dimension |
260mm(D) x 200mm(W) x 260mm(H) |
Net weight |
Appr. 5 kg |
Order Info
Scope of delivery
|
Optional Accessories
|
Image gallery
|
|
Baluntech BL677 Portable Infrared Calibration Source
BL677 Portable Infrared Calibration Source
|
Temperature range 50℃ to 500℃ Emissivity is better than 0.995 Temperature uniformity is up to 0.15℃ 0.1℃ High temperature control stability 65 mm big aperture diameter is compliance with most of D:S Built-in temperature correction function Robust construction |
Overview
The BL677 is a portable blackbody calibration source utilizing a digital indicating temperature ambient 50 to 500℃ (122F to 1292F). A precision platinum RTD temperature sensor is embedded in the blackbody emitter, providing high accuracy and repeatability. The temperature controller uses the industry standard PID algorithms to control the emitter temperature to within 0.1℃ of the set points. The black body emitter mechanism uses a resistive heating device that provides a long life, short stabilization times, and stable temperature control. |
Applications
Infrared temperature sensors
Infrared thermal imaging systems
Spectrographic analysers
Radio meters
Flux meter
Specifications
Temperature Range |
500℃ to 700℃ (122F to 1292F) |
Aperture diameter |
65 mm |
Emissivity |
> 0.995 |
Distance from tube to target |
250 mm |
Display resolution |
0.1℃ |
Control stability (10 min) |
±0.1℃ or 0.1%t (whichever is greater) |
Blackbody uniformity |
0.15℃ or 0.15%t (whichever is greater) |
Heat cavity shape |
End closed tube |
Control method |
Digital PID controller |
Temperature sensor |
Precision Platinum RTD |
Power supply |
220V AC, 1000 WA |
Interface |
RS232 |
Heat up time |
1.5 hour from ambient to 700℃ |
Calibration method |
Pyrometric standard calibration |
Dimension |
360mm(D) x 260mm(W) x 400mm(H) |
Net weight |
Appr. 15 kg |
Order Info
Scope of delivery
|
Optional Accessories
|
Image gallery
|
|
Baluntech BL765 Portable Infrared Calibration Source
BL675 Portable Infrared Calibration Source
|
Temperature range 50 to 500℃ 150 mm big aperture diameter 0.2℃ high temperature uniformity Built-in temperature correction function Robust design, easy to carry |
Overview
The BL675 is a portable blackbody calibration source utilizing a digital indicating temperature ambient 50 to 500℃ (122F to 932F). A precision platinum RTD temperature sensor is embedded in the blackbody emitter, providing high accuracy and repeatability. The temperature controller uses the industry standard PID algorithms to control the emitter temperature to within 0.1℃ of the set points. The black body emitter mechanism uses a resistive heating device that provides a long life, short stabilization times, and stable temperature control. |
Applications
Infrared temperature sensors
Infrared thermal imaging systems
Spectrographic analysers
Radio meters
Flux meter
Specifications
|
Order Info
Scope of delivery
|
Optional Accessories
|
Image gallery
|
|
BL678 Portable Infrared Calibration Source
BL678 Portable Infrared Calibration Source
Temperature range 300℃ to 1200℃ Emissivity is better than 0.995 Temperature uniformity is up to 0.15℃ 50 mm aperture diameter is compliance with most of D:S Build-in temperature correction function |
Overview
The BL678 is a portable blackbody calibration source utilizing a digital indicating temperature ambient 300 to 1200℃ (572F to 2192F). A precision platinum thermocouple N temperature sensor is embedded in the blackbody emitter, providing high accuracy and repeatability. The temperature controller uses the industry standard PID algorithms to control the emitter temperature to within 0.1℃ of the set points. The black body emitter mechanism uses a resistive heating device that provides a long life, short stabilization times, and stable temperature control. |
Applications
Infrared temperature sensors
Infrared thermal imaging systems
Spectrographic analysers
Radio meters
Flux meter
Specifications
Temperature Range |
300℃ to 1200℃ (572F to 2192F) |
Aperture diameter |
50 mm |
Emissivity |
> 0.995 |
Accuracy |
> 0.1℃ |
Display resolution |
0.1℃ |
Control stability (10 min) |
±0.1℃ or 0.1%t (whichever is greater) |
Blackbody uniformity |
0.15℃ or 0.15%t (whichever is greater) |
Heat cavity shape |
End closed tube |
Control method |
Digital PID controller |
Temperature sensor |
Precision N thermocouple |
Power supply |
110-230V AC, 1000 WA |
Interface |
RS232 |
Warm up time |
1.5 hour from ambient to 1200℃ |
Calibration method |
Pyrometric standard calibration |
Dimension |
350mm(D) x 220mm(W) x 260mm(H) |
Net weight |
Appr. 25 kg |
Order Info
Scope of delivery
|
Optional Accessories
|
Image gallery
|
|
BL670 Mini Blackbody Calibration Source
BL670 Portable Infrared Calibrator / Black Body
|
Overview
|
The BL670 is a small size blackbody calibration source utilizing a digital indicating temperature ambient 35℃ to 45℃ (95 to 113F). A precision platinum RTD temperature sensor is embedded in the blackbody emitter, providing high accuracy and repeatability. The temperature controller uses the industry standard PID algorithms to control the emitter temperature to within 0.1℃ of the set points. The black body emitter mechanism uses a resistive heating device that provides a long life, short stabilization times, and stable temperature control. |
Applications
Calibrate radiation thermometer
Infrared temperature sensors
Specifications
|
Order info
Scope of delivery
BL670 portable blackbody calibration source
Power adapter as standard 110-240V AC
Factory calibration report
Optional Accessories
Accredited calibration certificate (P/N: 9000-670)
RS485 interface function for BL670 (P/N: 2231)
Tripod with carrying bag (P/N:670-TP)
Image gallery
|
BL761 Portable Infrared Calibrator / Black Body
BL671 Portable Infrared Calibrator / Black Body
|
Overview
The BL671 is a small size blackbody calibration source utilizing a digital indicating temperature ambient 30℃ to 50℃ (86F to 122F). A 70x70 mm size ridged plate is heated or cooled with an internal solid-state thermoelectric heat pump. It has a built-in digital temperature controller to provide accurate, stable temperature as well as to provides readout. |
Applications
|
|
Specifications
Temperature Range |
30℃ to 50℃ (32F to 122F) |
Aperture size |
70 mm * 70 mm |
Emissivity |
0.97 ± 0.02 |
Display accuracy |
± 0.05℃, (uncertainty is 0.2℃, K=2) |
Display resolution |
0.01℃ |
Control stability |
± 0.05℃ after 10 minutes |
Blackbody uniformity |
± 0.05℃ |
Heat cavity shape |
Plat Plate |
Heat up time |
10 minute from ambient to 50℃ |
Control method |
Digital PID controller with readout |
Temperature sensor |
Precison platinum RTD |
Power supply |
110-220V AC, 50Hz, 60W |
Interface |
RS232 |
Dimension |
250mm(D) x 140mm(W) x 180mm(H) |
Net weight |
Appr. 2 kg |
Order info
SCOPE OF DELIVERY
BL671 Portable blackbody calibration source with carrying case
Power adapter as standard 110-240V AC
Factory calibration report
OPTIONAL ACCESSORIES
USB into RS232 adapter (P/N:1622)
Accredited calibration certificate (P/N: 9000-671)
Tripod with carrying bag (P/N: 67X-TP)