• Home
  • Youtube
  • About us
  • Contact
  • Peta Situs
  • Download
www.pttriwi.com
  • TEMPERATURE  
    • TEMPERATURE CALIBRATORS
    • BlackBody / Infrared calibration Source  
      • BlackBody calibration temperature infrared body
      • BlackBody / Infrared calibration Source
    • Temperature Data Loggers
    • Multi-channel Temperature Meter
    • Thermometer Readout and SPRTs
    • THERMOMETER and SENSORS
    • Thermocouple and Connector
  • PRESSURE  
    • Automatic Pressure Calibrators
    • Digital Pressure Calibrators / Gauges
    • Pneumatic Pressure Test/Calibration Pumps
    • Hydraulic Pressure Test Calibration pumps
    • Pressure Controller
    • Digital Pressure Module
    • Pressure Data Loggers
    • DWT ( Dead Weight Tester)
  • ENVIRONMENTAL  
    • KAYMONT RH GENERATOR
    • TRACEABLE  
      • Traceable Hygrometer
      • Traceable Barometer
    • TEMPERATURE - HUMIDITY DATA LOGGERS
    • THERMOHYGROMETERS
    • GAS DETECTION EQUIPMENTS
    • HUMIDITY CALIBRATOR
  • ELECTRICALS  
    • SIMULATOR / PROCESS CALIBRATORS
    • MULTIFUNCTION CALIBRATORS
    • POWER CALIBRATOR
    • POWER QUALITY ANALYZER
    • Impedance standards and calibrators
    • PROGRAMMABLE DECADES
  • BALANCE and TEST WEIGHTS  
    • HAFNER TEST WEIGHTS
    • ACCURATE TEST WEIGHTS
    • BALANCES
    • MOISTURE ANALYZERS
  • FREQUENCY  
    • STOPWATCH CALIBRATORS
    • SIGNAL GENERATORS
    • ANALYZER
    • TACHOMETER and VIBRATION
  • OPTICAL INSTRUMENTS
  • OTHERS PRODUCTS
  • Additel  
    • TEMPERATURE CALIBRATORS
    • AUTOMATED PRESSURE CALIBRATORS
    • DIGITAL PRESSURE CALIBRATOR/GAUGES
    • Pneumatic Test Pumps
    • Hydraulic Test Pumps
    • MULTIFUNCTION PROCESS CALIBRATORS
    • PRESSURE CONTROLLERS
    • ADAPTOR PRESSURE MODULE SOFTWARE
    • Thermometer Readout
    • Additel Products
    • ADT875 Temperature Calibrator  
      • ADT875-155
      • ADT875-350
      • ADT875-660
    • AdT 76X Automatic Pressure Calibrators  
      • ADT761A
      • ADT760
      • ADT761
  • AccuMac  
    • AccuMac Products
    • Digital Thermometer Readouts  
      • AM8060 Precision Thermometer
      • AM8040 Precision Thermometer
      • AM8010 Handheld Thermometer
    • SPRT Temperature Sensors/Probes  
      • AM1960/1950 Quartz SPRTs
      • AM1880 Metal-Sheath SPRT
      • AM1968 Capsule SPRT
      • AM1860/1850 Metal SPRTs
      • AM1760/1762 Secondary SPRTs
    • Secondary Reference PRT Sensors/Probes   
      • AM1751 Secondary Reference PRT
      • AM1730 Secondary Reference PRT
      • AM1710 Secondary Reference PRT
    • Precision Industrial PRT Sensors/Probes  
      • AM1660/1640/1620 Precision Industrial PRTs
      • AM1610 Precision Industrial PRT
    • Reference Standard Thermocouple Sensor/Probe
    • Gradient PRT Sensor/Probe
    • Full Immersion PRT Sensor/Probe  
      • AM1612 Full Immersion PRT
      • AM1643 Full Immersion PRT
  • Accurate  
    • Standard Weight  
      • E1 Class Weight
      • E2 Class Weight
      • F1 Class Weight
      • F2 Class Weight
      • M1 Class Weight
    • ODM Weight  
      • Stainless Steel ODM Weight
  • Aihua Sound  
    • Sound Level Meters  
      • AWA6228+
      • AWA5688
      • AWA5661
      • AWA5636-0
      • AWA5636-1
      • AWA5636-2
      • AWA5636-3
      • AWA5636-4
    • Noise Dosimeter  
      • ASV5910-R Noise Dosimeter Recorder
      • ASV5910+-1 Noise Dosimeter Measurement Kit
      • ASV5910+-1 Noise Dosimeter
      • ASV5910+-2 Noise Dosimeter
      • ASV5910+-3 Noise Dosimeter
      • ASV5910+-2 Noise Dosimeter Measurement Kit
    • Real Time Signal Analyzer  
      • AWA 6291
    • Sound Calibrator  
      • AWA6221A (94dB & 114dB)
      • AWA6223S/F
      • AWA6221B
      • AWA6221C
    • Condenser Microphone& Preamplifier  
      • AWA14400
      • AWA14604
    • Vibration Measuring Instrument  
      • AWA5936
    • Electroacoustic Measuring Instrument  
      • AWA6160~6163
      • High leakage ears
      • Low leakage ears (outer) simulator
    • Other acoustic measuring instrument  
      • AWA1650
  • Applent Instruments  
    • Multi-channel Temperature Meter  
      • CKT-7000 Multi-channel Temperature Data Logger
      • APPLENT 4500 Multi-channel Temperature Data Logger
      • APPLENT 4200 Handheld Multi-channel Temperature Data Logger
      • APPLENT Handheld Multi-channel Temperature Data Logger
    • Blackbody radiation source  
      • CKT385-050 Blackbody radiation source
  • Baluntech   
    • DWT ( Dead Weight Tester)  
      • Pneumatic Dead weight Tester
      • Vacuum Dead weight Tester
      • Low Pressure Dead weight Tester
      • Differential Pressure Dead Weight Tester
      • Portable Pressure Dead weight Tester
      • Hydraulic Pressure Dead weight Tester
      • Water Pressure Dead weight Tester
      • Hydraulic Pressure Balance
    • Clinical Blackbody Calibration Source  
      • BL670 Mini Blackbody Calibration Source
      • BL671 Portable Blackbody Calibration Source
      • BL672S Isothermal Blackbody Calibration Source
      • BL672D Dual Blackbody Calibration Source
    • BlackBody / Infrared calibration Source  
      • BL675 BlackBody / Infrared calibration Source
      • BL676 BlackBody / Infrared calibration Source
      • BL677 BlackBody / Infrared calibration Source
      • BL678 BlackBody / Infrared calibration Source
  • Bel Enggineering  
    • PRODUCTS  
      • BALANCES
      • MOISTURE ANALYZERS
    • SEMI-MICRO BALANCES  
      • M5
      • HPBG
      • HPB
    • ANALYTICAL BALANCES  
      • M5
      • M and MG
    • PRECISION BALANCE S  
      • M5
      • M and MG
      • MG and MGW
      • L and LG
      • LW and LWG
      • S portable
      • ES portable Series
    • High Capacity balances  
      • High Capacity balances
    • Moisture analyzers  
      • M5-Thermo
      • i-Thermo G
      • i-Thermo
    • Density Index Balance  
      • M5-iDens
    • PIPETTE CHECKING  
      • COMPLETE SYSTEM FOR PIPETTE CHECKING
    • Accessories  
      • Accessories
  • CEM   
    • Infra Red Thermometer Calibrator
  • ETI  
    • Calibrators  
      • dry-well heat source calibrators
      • Calibration Water Bath
    • Digital Thermometers  
      • Therma Elite Industrial Thermometer
      • Therma Waterproof Thermometer
      • Therma Differential Thermometer
      • MicroTherma 1 microprocessor thermometer
      • Precision Plus PT100 high accuracy thermometer
      • TempTest 1 Smart Thermometer
    • Digital Infra Red Thermometer  
      • High Temperature Infrared Thermometer
      • Infra-red thermometer kit
    • Thermometer Probe  
      • Heavy duty surface temperature probe
      • Ribbon surface temperature probe
      • High temperature thermometer probe
      • Fast response temperature probe
      • Roller surface temperature probe
      • PT100 Temperature probe
    • Thermohygrometer  
      • Therma-Hygrometer
  • Graphtec  
    • Midi Data Logger  
      • 10-ch midi data logger
      • 20-ch midi data logger
    • Hioki  
      • LR8410-20
  • Hafner  
    • Primary Standard weights   
      • Class E0
    • Standard weights   
      • Class E1
      • Class E2
    • High precision weights  
      • Class F1
      • Class F2
    • Precision weights  
      • Class M1
  • Hotech  
    • Infrared Tympanic Thermometer Black Body  
      • HOTECH 320 Thermometer Calibration Bath
      • HOTECH 322 Precise Tympanic Thermometers Calibration
      • HOTECH 323 Miniature Calibration Bath for Ear & Clinical Thermometer
      • HOTECH 3301 Infrared Tympanic Thermometer Calibration Blackbody
      • HOTECH 336 Infrared Tympanic Thermometer Calibration Blackbody
    • BlackBody / Infrared calibration Source  
      • HOTECH 360 Low Temperature High Uniformity Blackbody
      • HOTECH 372 Black body Calibration Source
      • HOTECH 383 Blackbody Calibration Source
      • HOTECH 384 Blackbody Calibration Source
      • HOTECH 385 Blackbody Calibration Source
      • HOTECH 390 Black body Calibration Source
      • HOTECH 391 Black body Calibration Source
      • HOTECH 392 Black body Calibration Source
  • Huato  
    • Temperature Data Logger  
      • S100-ET
      • S500-EPT
      • HE804
      • S220-T8
    • Temperature dan Humidity Data Logger  
      • S100TH
      • HE174
      • S500TH
      • HE815-TH / HE815-EX /HE825-EX
    • Wireless Data Logger  
      • HE 24R
      • S400W
      • S500-WIFI
    • Thermohygrometer  
      • A2000
      • HE710 / HE715
    • GSM Alarm Temperature Humidity Data Logger  
      • S520
      • S630
    • Gas Detection  
      • S654
      • PM2.5/PM10
      • S653
      • S635
      • S150DP
      • HE5201
  • Leyro  
    • Calibration Temperature  
      • LCA30 Calibration Micro baths
      • LCA30 COOL Calibration Micro baths
      • LCA50 Calibration Micro baths
      • LCB30 Calibration Micro baths
      • LCB30 COOL Calibration Micro baths
      • LCB50 Calibration Micro baths
  • Meatest  
    • ELECTRICAL CALIBRATORS  
      • M143 PORTABLE MULTIFUNCTION CALIBRATOR
      • M142 MULTIFUNCTION CALIBRATOR
      • M140 MULTIFUNCTION CALIBRATOR
      • M151 High current calibrator
      • M160 Precision DC Calibrator
      • M505 Process Calibrator
    • POWER CALIBRATOR  
      • POWER CALIBRATOR
    • Impedance standards and calibrators  
      • MTE Laboratory Impedance Standards
      • M530 RF Resistance Standards
      • M550 Impedance Calibrator
      • M6x2 Real-Resistance Decades
    • Programmable Decades  
      • M191 High Resistance Decade - Insulation Tester Calibrator
      • M192 Programmable AC/DC Resistance Loads
      • M194 High Resistance Decade
      • M6x1 Real-Resistance RTD Simulators
      • M6x2 Real-Resistance Decades
      • M109R High Resistance Decade
      • M520 Programmable Capacitance Decade
      • M525 Programmable Capacitance Decade
      • M602 - M622 Legacy Real-Resistance Decades
    • Software for automated calibration
    • Accessories
  • Monarch  
    • Tachometer
    • Vibration Meter
  • Metrology Jingstone  
    • METROLOGY DIMENSIONS CALIBRATORS
  • Sansel  
    • TACHOMETER CALIBRATOR   
      • RPMC 1700-2A 6.000 RPM
      • RPMC 1700-3A 8.000 RPM
      • RPMC 1700-4A - 12000RPM
    • HUMIDITY CALIBRATOR
    • MICRO-BATH TEMPERATURE CALIBRATOR
  • Suin Instruments  
    • Calibrator  
      • SF2002
      • ST2050
    • Function/Arbitrary waveform Generators  
      • TFG2900A Series
      • TFG3900A Series
      • TFG6900A Series
      • TFG1900A Series
      • TFG1900B Series
    • RF Signal Generators  
      • TFG3600 Series
      • SU3630
    • Pulse/Pattern Generators  
      • SU5000 Series
    • Microwave Signal Generator  
      • TFG368X Microwave Signal Generator
    • Power Quality Analyzer  
      • SA2100
      • SA2200
    • Spectrum Analyzers  
      • SA9100A / SA9200A Series
    • Frequency Counter  
      • SS7406
      • SS7000 Series
    • Frequency Characteristic Analyzer  
      • SA1000
    • Meter  
      • Millivolt Meter SM2100 Series
      • Digital Multimeter SA5052 / SA5061 Series
    • Power Supply  
      • SK33231/33251
      • SK3323/3325
      • SK3323J/3325J Series
      • SK13530
  • Starna  
    • PRODUCTS
    • UV-VIS REFERENCES  
      • Absorbance References  
        • Metal On Quartz Filters for UV Visible
        • Neutral Density Filter
      • Wavelength References  
        • Holmium Glass
        • Didymium Glass
        • Wide Range Wavelength Reference
      • Stray Light (Stray Radiant Energy) References  
        • Starna Stray Light Glasses
    • NIR REFERENCES  
      • Absorbance References
      • Wavelength References
    • DMV-BIO CELL  
      • DMV-BIO CELL
  • TecnoSoft  
    • Tecnosoft SterilDisk Temperature Data Loggers  
      • SterilDisk
      • SterilDisk Probe
      • SterilDisk Probe with thread
      • SterilDisk Flexible
    • Tecnosoft S-Micro Temperature Data Loggers  
      • S-Micro
      • S-Micro L
      • S-Micro XL
    • Tecnosoft S-MicroW Temperature Data Loggers  
      • S-MicroW L
      • S-MicroW L Flexible
      • S-MicroW L Bendable 2 mm
      • S-MicroW L Ultra Freeze
      • S-MicroW XL
      • S-MicroW XL Flexible
      • S-MicroW XL Bendable 2mm
      • S-MicroW XL Ultra Freeze
    • Tecnosoft Pressure Data Loggers  
      • PressureDisk
      • PressureDisk 05
      • PressPDF-L
      • Pirani Vacuum Logger
      • Pirani Vacuum Logger with thread
    • Tecnosoft Humidity Data Loggers  
      • RHTemp80 L
      • RHTemp80XL
      • RHTemp125 L
      • RHTemp125 XL
    • Software
    • Accessories
  • WAHL  
    • Temperature Calibration Bath  
      • CLB30 Low Temperature Calibration Bath
      • CLB50 High Temperature Calibration Bath
      • CLB31 Advance Low Temperature Calibration Bath
      • CLB51 Advance High Temperature Calibration Bath
    • Simulator Temperature Calibrator  
      • TC621 Simulator Thermocouple Calibrator
      • TC622 Simulator RTD Calibrator
    • Thermometer Thermocouple and RTD   
      • TM630A Thermometer Thermocouple & RTD
      • TM612A Pocket RTD Thermometer
      • TM602A Pocket Thermocouple Thermometer
  • HALAMAN DEPAN
  • Hot products
  • HOBO  
    • HOBO TEMP/RH DATA LOGGER
  • GFUVE  
    • POWER SOURCE
    • ENERGY METER CALIBRATION
  • Home
  • Youtube
  • About us
  • Contact
  • Peta Situs
  • Download
  • AccuMac

Information

Categories

  • TEMPERATURE
    • TEMPERATURE CALIBRATORS
    • BlackBody / Infrared calibration Source
      • BlackBody calibration temperature infrared body
      • BlackBody / Infrared calibration Source
    • Temperature Data Loggers
    • Multi-channel Temperature Meter
    • Thermometer Readout and SPRTs
    • THERMOMETER and SENSORS
    • Thermocouple and Connector
  • PRESSURE
    • Automatic Pressure Calibrators
    • Digital Pressure Calibrators / Gauges
    • Pneumatic Pressure Test/Calibration Pumps
    • Hydraulic Pressure Test Calibration pumps
    • Pressure Controller
    • Digital Pressure Module
    • Pressure Data Loggers
    • DWT ( Dead Weight Tester)
  • ENVIRONMENTAL
    • KAYMONT RH GENERATOR
    • TRACEABLE
      • Traceable Hygrometer
      • Traceable Barometer
    • TEMPERATURE - HUMIDITY DATA LOGGERS
    • THERMOHYGROMETERS
    • GAS DETECTION EQUIPMENTS
    • HUMIDITY CALIBRATOR
  • ELECTRICALS
    • SIMULATOR / PROCESS CALIBRATORS
    • MULTIFUNCTION CALIBRATORS
    • POWER CALIBRATOR
    • POWER QUALITY ANALYZER
    • Impedance standards and calibrators
    • PROGRAMMABLE DECADES
  • BALANCE and TEST WEIGHTS
    • HAFNER TEST WEIGHTS
    • ACCURATE TEST WEIGHTS
    • BALANCES
    • MOISTURE ANALYZERS
  • FREQUENCY
    • STOPWATCH CALIBRATORS
    • SIGNAL GENERATORS
    • ANALYZER
    • TACHOMETER and VIBRATION
  • OPTICAL INSTRUMENTS
  • OTHERS PRODUCTS
  • Additel
    • TEMPERATURE CALIBRATORS
    • AUTOMATED PRESSURE CALIBRATORS
    • DIGITAL PRESSURE CALIBRATOR/GAUGES
    • Pneumatic Test Pumps
    • Hydraulic Test Pumps
    • MULTIFUNCTION PROCESS CALIBRATORS
    • PRESSURE CONTROLLERS
    • ADAPTOR PRESSURE MODULE SOFTWARE
    • Thermometer Readout
    • Additel Products
    • ADT875 Temperature Calibrator
      • ADT875-155
      • ADT875-350
      • ADT875-660
    • AdT 76X Automatic Pressure Calibrators
      • ADT761A
      • ADT760
      • ADT761
  • AccuMac
    • AccuMac Products
    • Digital Thermometer Readouts
      • AM8060 Precision Thermometer
      • AM8040 Precision Thermometer
      • AM8010 Handheld Thermometer
    • SPRT Temperature Sensors/Probes
      • AM1960/1950 Quartz SPRTs
      • AM1880 Metal-Sheath SPRT
      • AM1968 Capsule SPRT
      • AM1860/1850 Metal SPRTs
      • AM1760/1762 Secondary SPRTs
    • Secondary Reference PRT Sensors/Probes
      • AM1751 Secondary Reference PRT
      • AM1730 Secondary Reference PRT
      • AM1710 Secondary Reference PRT
    • Precision Industrial PRT Sensors/Probes
      • AM1660/1640/1620 Precision Industrial PRTs
      • AM1610 Precision Industrial PRT
    • Reference Standard Thermocouple Sensor/Probe
    • Gradient PRT Sensor/Probe
    • Full Immersion PRT Sensor/Probe
      • AM1612 Full Immersion PRT
      • AM1643 Full Immersion PRT
  • Accurate
    • Standard Weight
      • E1 Class Weight
      • E2 Class Weight
      • F1 Class Weight
      • F2 Class Weight
      • M1 Class Weight
    • ODM Weight
      • Stainless Steel ODM Weight
  • Aihua Sound
    • Sound Level Meters
      • AWA6228+
      • AWA5688
      • AWA5661
      • AWA5636-0
      • AWA5636-1
      • AWA5636-2
      • AWA5636-3
      • AWA5636-4
    • Noise Dosimeter
      • ASV5910-R Noise Dosimeter Recorder
      • ASV5910+-1 Noise Dosimeter Measurement Kit
      • ASV5910+-1 Noise Dosimeter
      • ASV5910+-2 Noise Dosimeter
      • ASV5910+-3 Noise Dosimeter
      • ASV5910+-2 Noise Dosimeter Measurement Kit
    • Real Time Signal Analyzer
      • AWA 6291
    • Sound Calibrator
      • AWA6221A (94dB & 114dB)
      • AWA6223S/F
      • AWA6221B
      • AWA6221C
    • Condenser Microphone& Preamplifier
      • AWA14400
      • AWA14604
    • Vibration Measuring Instrument
      • AWA5936
    • Electroacoustic Measuring Instrument
      • AWA6160~6163
      • High leakage ears
      • Low leakage ears (outer) simulator
    • Other acoustic measuring instrument
      • AWA1650
  • Applent Instruments
    • Multi-channel Temperature Meter
      • CKT-7000 Multi-channel Temperature Data Logger
      • APPLENT 4500 Multi-channel Temperature Data Logger
      • APPLENT 4200 Handheld Multi-channel Temperature Data Logger
      • APPLENT Handheld Multi-channel Temperature Data Logger
    • Blackbody radiation source
      • CKT385-050 Blackbody radiation source
  • Baluntech
    • DWT ( Dead Weight Tester)
      • Pneumatic Dead weight Tester
      • Vacuum Dead weight Tester
      • Low Pressure Dead weight Tester
      • Differential Pressure Dead Weight Tester
      • Portable Pressure Dead weight Tester
      • Hydraulic Pressure Dead weight Tester
      • Water Pressure Dead weight Tester
      • Hydraulic Pressure Balance
    • Clinical Blackbody Calibration Source
      • BL670 Mini Blackbody Calibration Source
      • BL671 Portable Blackbody Calibration Source
      • BL672S Isothermal Blackbody Calibration Source
      • BL672D Dual Blackbody Calibration Source
    • BlackBody / Infrared calibration Source
      • BL675 BlackBody / Infrared calibration Source
      • BL676 BlackBody / Infrared calibration Source
      • BL677 BlackBody / Infrared calibration Source
      • BL678 BlackBody / Infrared calibration Source
  • Bel Enggineering
    • PRODUCTS
      • BALANCES
      • MOISTURE ANALYZERS
    • SEMI-MICRO BALANCES
      • M5
      • HPBG
      • HPB
    • ANALYTICAL BALANCES
      • M5
      • M and MG
    • PRECISION BALANCE S
      • M5
      • M and MG
      • MG and MGW
      • L and LG
      • LW and LWG
      • S portable
      • ES portable Series
    • High Capacity balances
      • High Capacity balances
    • Moisture analyzers
      • M5-Thermo
      • i-Thermo G
      • i-Thermo
    • Density Index Balance
      • M5-iDens
    • PIPETTE CHECKING
      • COMPLETE SYSTEM FOR PIPETTE CHECKING
    • Accessories
      • Accessories
  • CEM
    • Infra Red Thermometer Calibrator
  • ETI
    • Calibrators
      • dry-well heat source calibrators
      • Calibration Water Bath
    • Digital Thermometers
      • Therma Elite Industrial Thermometer
      • Therma Waterproof Thermometer
      • Therma Differential Thermometer
      • MicroTherma 1 microprocessor thermometer
      • Precision Plus PT100 high accuracy thermometer
      • TempTest 1 Smart Thermometer
    • Digital Infra Red Thermometer
      • High Temperature Infrared Thermometer
      • Infra-red thermometer kit
    • Thermometer Probe
      • Heavy duty surface temperature probe
      • Ribbon surface temperature probe
      • High temperature thermometer probe
      • Fast response temperature probe
      • Roller surface temperature probe
      • PT100 Temperature probe
    • Thermohygrometer
      • Therma-Hygrometer
  • Graphtec
    • Midi Data Logger
      • 10-ch midi data logger
      • 20-ch midi data logger
    • Hioki
      • LR8410-20
  • Hafner
    • Primary Standard weights
      • Class E0
    • Standard weights
      • Class E1
      • Class E2
    • High precision weights
      • Class F1
      • Class F2
    • Precision weights
      • Class M1
  • Hotech
    • Infrared Tympanic Thermometer Black Body
      • HOTECH 320 Thermometer Calibration Bath
      • HOTECH 322 Precise Tympanic Thermometers Calibration
      • HOTECH 323 Miniature Calibration Bath for Ear & Clinical Thermometer
      • HOTECH 3301 Infrared Tympanic Thermometer Calibration Blackbody
      • HOTECH 336 Infrared Tympanic Thermometer Calibration Blackbody
    • BlackBody / Infrared calibration Source
      • HOTECH 360 Low Temperature High Uniformity Blackbody
      • HOTECH 372 Black body Calibration Source
      • HOTECH 383 Blackbody Calibration Source
      • HOTECH 384 Blackbody Calibration Source
      • HOTECH 385 Blackbody Calibration Source
      • HOTECH 390 Black body Calibration Source
      • HOTECH 391 Black body Calibration Source
      • HOTECH 392 Black body Calibration Source
  • Huato
    • Temperature Data Logger
      • S100-ET
      • S500-EPT
      • HE804
      • S220-T8
    • Temperature dan Humidity Data Logger
      • S100TH
      • HE174
      • S500TH
      • HE815-TH / HE815-EX /HE825-EX
    • Wireless Data Logger
      • HE 24R
      • S400W
      • S500-WIFI
    • Thermohygrometer
      • A2000
      • HE710 / HE715
    • GSM Alarm Temperature Humidity Data Logger
      • S520
      • S630
    • Gas Detection
      • S654
      • PM2.5/PM10
      • S653
      • S635
      • S150DP
      • HE5201
  • Leyro
    • Calibration Temperature
      • LCA30 Calibration Micro baths
      • LCA30 COOL Calibration Micro baths
      • LCA50 Calibration Micro baths
      • LCB30 Calibration Micro baths
      • LCB30 COOL Calibration Micro baths
      • LCB50 Calibration Micro baths
  • Meatest
    • ELECTRICAL CALIBRATORS
      • M143 PORTABLE MULTIFUNCTION CALIBRATOR
      • M142 MULTIFUNCTION CALIBRATOR
      • M140 MULTIFUNCTION CALIBRATOR
      • M151 High current calibrator
      • M160 Precision DC Calibrator
      • M505 Process Calibrator
    • POWER CALIBRATOR
      • POWER CALIBRATOR
    • Impedance standards and calibrators
      • MTE Laboratory Impedance Standards
      • M530 RF Resistance Standards
      • M550 Impedance Calibrator
      • M6x2 Real-Resistance Decades
    • Programmable Decades
      • M191 High Resistance Decade - Insulation Tester Calibrator
      • M192 Programmable AC/DC Resistance Loads
      • M194 High Resistance Decade
      • M6x1 Real-Resistance RTD Simulators
      • M6x2 Real-Resistance Decades
      • M109R High Resistance Decade
      • M520 Programmable Capacitance Decade
      • M525 Programmable Capacitance Decade
      • M602 - M622 Legacy Real-Resistance Decades
    • Software for automated calibration
    • Accessories
  • Monarch
    • Tachometer
    • Vibration Meter
  • Metrology Jingstone
    • METROLOGY DIMENSIONS CALIBRATORS
  • Sansel
    • TACHOMETER CALIBRATOR
      • RPMC 1700-2A 6.000 RPM
      • RPMC 1700-3A 8.000 RPM
      • RPMC 1700-4A - 12000RPM
    • HUMIDITY CALIBRATOR
    • MICRO-BATH TEMPERATURE CALIBRATOR
  • Suin Instruments
    • Calibrator
      • SF2002
      • ST2050
    • Function/Arbitrary waveform Generators
      • TFG2900A Series
      • TFG3900A Series
      • TFG6900A Series
      • TFG1900A Series
      • TFG1900B Series
    • RF Signal Generators
      • TFG3600 Series
      • SU3630
    • Pulse/Pattern Generators
      • SU5000 Series
    • Microwave Signal Generator
      • TFG368X Microwave Signal Generator
    • Power Quality Analyzer
      • SA2100
      • SA2200
    • Spectrum Analyzers
      • SA9100A / SA9200A Series
    • Frequency Counter
      • SS7406
      • SS7000 Series
    • Frequency Characteristic Analyzer
      • SA1000
    • Meter
      • Millivolt Meter SM2100 Series
      • Digital Multimeter SA5052 / SA5061 Series
    • Power Supply
      • SK33231/33251
      • SK3323/3325
      • SK3323J/3325J Series
      • SK13530
  • Starna
    • PRODUCTS
    • UV-VIS REFERENCES
      • Absorbance References
        • Metal On Quartz Filters for UV Visible
        • Neutral Density Filter
      • Wavelength References
        • Holmium Glass
        • Didymium Glass
        • Wide Range Wavelength Reference
      • Stray Light (Stray Radiant Energy) References
        • Starna Stray Light Glasses
    • NIR REFERENCES
      • Absorbance References
      • Wavelength References
    • DMV-BIO CELL
      • DMV-BIO CELL
  • TecnoSoft
    • Tecnosoft SterilDisk Temperature Data Loggers
      • SterilDisk
      • SterilDisk Probe
      • SterilDisk Probe with thread
      • SterilDisk Flexible
    • Tecnosoft S-Micro Temperature Data Loggers
      • S-Micro
      • S-Micro L
      • S-Micro XL
    • Tecnosoft S-MicroW Temperature Data Loggers
      • S-MicroW L
      • S-MicroW L Flexible
      • S-MicroW L Bendable 2 mm
      • S-MicroW L Ultra Freeze
      • S-MicroW XL
      • S-MicroW XL Flexible
      • S-MicroW XL Bendable 2mm
      • S-MicroW XL Ultra Freeze
    • Tecnosoft Pressure Data Loggers
      • PressureDisk
      • PressureDisk 05
      • PressPDF-L
      • Pirani Vacuum Logger
      • Pirani Vacuum Logger with thread
    • Tecnosoft Humidity Data Loggers
      • RHTemp80 L
      • RHTemp80XL
      • RHTemp125 L
      • RHTemp125 XL
    • Software
    • Accessories
  • WAHL
    • Temperature Calibration Bath
      • CLB30 Low Temperature Calibration Bath
      • CLB50 High Temperature Calibration Bath
      • CLB31 Advance Low Temperature Calibration Bath
      • CLB51 Advance High Temperature Calibration Bath
    • Simulator Temperature Calibrator
      • TC621 Simulator Thermocouple Calibrator
      • TC622 Simulator RTD Calibrator
    • Thermometer Thermocouple and RTD
      • TM630A Thermometer Thermocouple & RTD
      • TM612A Pocket RTD Thermometer
      • TM602A Pocket Thermocouple Thermometer
  • HALAMAN DEPAN
  • Hot products
  • HOBO
    • HOBO TEMP/RH DATA LOGGER
  • GFUVE
    • POWER SOURCE
    • ENERGY METER CALIBRATION
  • ADT875 and ADT878

Testimonial

» lihat testimonial
» isi testimonial
berhasil ditambahkan ke keranjang.

AccuMac

Refine Search

AccuMac Products
Digital Thermometer Readouts
SPRT Temperature Sensors/Probes
Secondary Reference PRT Sensors/Probes
Precision Industrial PRT Sensors/Probes
Reference Standard Thermocouple Sensor/Probe
Gradient PRT Sensor/Probe
Full Immersion PRT Sensor/Probe
Display :
  • «
  • 1
  • »
Sort By:
AccuMac AM1210  Type S Reference Standard Thermocouple

AccuMac AM1210 Type S Reference Standard Thermocouple

AccuMac AM1210 - Type S Reference Standard Thermocouple

  

Affordable reference standard

Type S

Short term stability: ±0.2 °C at 1084.62°C

Temperature range: 0 °C to 1300 °C

Overview

AM1210 Reference Standard Type S Thermocouple is made from reference grade platinum and platinum-rhodium alloy. It covers a temperature range of 0 °C to 1300 °C with short term stability of 0.2 °C all the way to Freezing Point of Copper (1084.62 °C). It is commonly used as reference standard to calibrate industrial thermocouples. All thermocouple wires and parts are specially cleaned and annealed before assembly. Every AM1210 thermocouple is fully annealed and tested again to meet the Tolerance criteria as specified in the tablebelow.  

 

Specifications

 

Temperature Range

0 °C to 1300 °C

Type

Type S: Platinum/10 % Rhodium vs. platinum

Long Term Drift

±0.6 °C at 1084.62 °C after 1 year typical usage

Tolerance (mV)

E(tCu)=10.575±0.015

E(tAl)=5.860+0.37(E(tCu)-10.575)±0.005

E(tZn)=3.447+0.18(E(tCu)-10.575) ±0.005

Short Term Stability

±0.2 °C at 1084.62 °C

Diameter of thermocouple wire

0.5 mm

Sheath Material

Quartz or Alumina

Sheath Dimensions

OD: 6 mm; Length: 500 mm

External Lead Wire

S type thermocouple wire, 500 mm

Protective Carrying Case

Included

 

Image Gallery

 

 

 

 

 

AccuMac AM1610  Precision Industrial PRT

AccuMac AM1610 Precision Industrial PRT

AccuMac AM1610

Precision Industrial PRT

  

  • Temperature range: -60 °C to 160 °C
  • Sensor Length: 30 mm
  • Accuracy: ±0.05 °C
  • Long term drift: ±0.04 °C
  • Short term stability: 0.01 °C
  • Durable and shock resistance
  •  Temperature Coefficient 0.00385
  • SST sheath
  • Quick response time
  • Customized dimensions available

Overview

With 30 mm long sensor, AM1610 series precision industrial PRT provides users an excellence temperature probe with extremely low stem conduction (heat loss along sheath) in precision temperature measurement. It is a great tool for measuring and testing the vertical temperature uniformity of heat sources.

AM1610 uses a special aged and tested 30-mm long sensing element to achieve the best performance in stability and repeatability. A unique assembly procedure provides the best balance among the hysteresis effect, mechanical shock and thermal shock performance. 

Specifications

 

Temperature Range

-60 °C to 160 °C

Resistance at 0 °C

Nominal 100 Ω

Temperature Coefficient

0.00385 Ω/ Ω/°C

Accuracy

±0.05 °C

Drift

±0.04 °C at 0 °C after 100 hours at 160 °C

Short Term Stability

±0.01 °C

Thermal Shock

±0.01 °C after 10 times thermal cycles from minimum to maximum temperatures

Hysteresis

<=0.01 °C

Self-heating

50 mW/°C

Response Time

5 seconds for 63% response to step change in water moving at 3 feet per second

Measurement Current

0.5 mA or 1 mA

Sensor Length

30 mm

Sensor Location

5 mm from tip

Insulation Resistance

>1000 MΩ at room temperature

Sheath Material

316 Stainless Steel

Dimension

1610-12: 0.25 inch X 12 inch (6.35 mm X 305 mm)

1610-9:  0.187 inch X 9 inch (4.75 mm X 229 mm)

External Leads

Teflontm – insulated copper wire, 4 leads, 2.5 meters

Handle Dimension

1610-12: 15 mm (OD) X 65 mm (L)

1610-9: 10 mm (OD) X 50 mm (L)

Handle Temperature Range*

-50 °C to 160 °C

Optional Calibration

NIST traceable calibration and data available per request:

1610-12: Ordering # 5017

Optional Accessories

 

Model

Description

9001

Wooden Carrying Case

 

Image Gallery

 

 

 

 

 

AccuMac AM1612  Full Immersion PRT

AccuMac AM1612 Full Immersion PRT

AccuMac AM1612 - Full Immersion PRT

 

  • Temperature range: -196 °C to 180 °C
  • Probe Length: 50 mm
  • Accuracy: ±0.05 °C at 0 °C
  • Long term drift: ±0.04 °C
  • Short term stability: 0.02 °C
  • Durable and shock resistance
  • Temperature Coefficient 0.00385
  • SST sheath

Overview

AM1612 full immersion PRT is uniquely designed to provide users an excellence temperature probe that can expose the transition junction and lead wires to an environment that covers the full PRT temperature range. The seal of probe prevents the ingress of moisture so that the probe can work in a humid condition or even under full immersion in common heat transfer fluids such as ethanol, silicone oil and mineral oil. 

AM1612 is small in size with probe length of 50 mm and diameter of 3 mm. A unique assembly procedure provides the best balance among the hysteresis effect, mechanical shock and thermal shock performance 

Specifications

 

Temperature Range

-196 °C to 180 °C

Resistance at 0 °C

Nominal 100 Ω

Temperature Coefficient

0.00385 Ω/ Ω/°C

Accuracy

±0.05 °C at 0 °C

Drift

±0.04 °C at 0 °C after 100 hours at 160 °C

Short Term Stability

±0.02 °C

Thermal Shock

±0.02 °C after 10 times thermal cycles from minimum to maximum temperatures

Hysteresis

<=0.01 °C

Self-heating

75 mW/°C

Response Time

4 seconds for 63% response to step change in water moving at 3 feet per second

Measurement Current

1 mA

Sensor Length

30 mm

Insulation Resistance

>1000 MΩ at room temperature

Sheath Material

Stainless Steel 316L

Dimension

0.125 inch X 2 inch (3 mm X 50 mm)

External Leads

Enameled copper wire protected by high temperature heat shrink tubing, 4 leads, 2.5 meters

Optional Calibration

NIST traceable calibration and data available per request

 

Optional Accessories

 

Model

Description

9001

Wooden Carrying Case

 

Image Gallery

 

 

 

 

 

AccuMac AM1643  Full Immersion PRT

AccuMac AM1643 Full Immersion PRT

AccuMac AM1643 - Full Immersion PRT

 

  • Temperature range: 0 °C to 420 °C
  • Accuracy: ±0.04 °C at 0 °C
  • Long term drift: ±0.04 °C
  • Short term stability: 0.02 °C
  • Transition junction and lead wire can withstand high temperature up to 420 °C
  • Temperature Coefficient 0.00385
  • Follow DIN/IEC-751 precisely
  • Inconel sheath
  • Quick response time

Overview

AM1643 full immersion PRT features a unique design that allows for the users to apply the probe together with its lead wire in a high temperature environment such as ovens or furnaces etc. It covers a wide range of temperature from 0 °C to 420 °C with amazing accuracy of ±0.04 °C at 0 °C, short term stability of ±0.02 °C and fast respond time of 5 seconds. 

To reach the best performance in stability and repeatability, the wire-wound sensing elements are specially designed to protect the platinum sensing wire from contamination at high temperature. A unique support structure and filling material provide the best balance among the hysteresis effect, mechanical shocks and thermal shock performance. This probe conforms to the DIN/IEC-751 curve precisely. 

 

Specifications

 

Temperature Range

0 °C to 420 °C                                      

Resistance at 0 °C

Nominal 100 Ω

Temperature Coefficient

0.00385 Ω/ Ω/°C

Accuracy*

±0.04 °C at 0 °C

±0.05 °C at 200 °C

±0.07 °C at 420 °C

Drift

±0.04 °C at 0 °C after 100 hours at 420 °C

Short Term Stability

±0.02 °C

Thermal Shock

±0.02 °C after 10 times thermal cycles from minimum to maximum temperatures

Hysteresis

<=0.01 °C

Self-heating

50 mW/°C

Response Time

5 seconds for 63% response to step change in water moving at 3 feet per second

Measurement Current

1 mA

Minimum immersion depth

50 mm

Maximum immersion depth

Dry medium: full immersion

Liquid medium: use protective tube if immersion depth reaches transition junction

Sensor Length

30 mm

Insulation Resistance

>500 MΩ at room temperature

Sheath Material

Inconeltm

Dimension

0.125 inch X 2 inch (3 mm X 50 mm)

External Leads

Four fiberglass insulation Ni-plated copper wires, 2.5 meters (longer lead wires are available per request)

Handle Dimension

7 mm (OD) X 30 mm (L)

Optional Calibration

NIST traceable calibration and data available per request: Ordering # 5012

 

Optional Accessories

 

Model

Description

9001

Wooden Carrying Case

 

Image Gallery

 

 

 

 

 

AccuMac AM1660/1640/1620  Precision Industrial PRTs 

AccuMac AM1660/1640/1620 Precision Industrial PRTs 

AccuMac AM1660/1640/1620 - Precision Industrial PRTs     

  

  • Temperature range: -200 °C to 670 °C
  • Accuracy: ±0.035 °C at 0 °C
  • Long term drift: ±0.04 °C
  • Short term stability: 0.01 °C
  • Durable and shock resistance
  • Temperature Coefficient 0.00385
  • Follow DIN/IEC-751 precisely
  • Inconel sheath
  • Quick response time
  • Customized dimensions available

Overview

AM1620/1640/1660 series precision industrial PRTs are top choices when price-to-performance is considered. They cover a wide range of temperature from -200 °C to 670 °C with amazing accuracy of ±0.035 °C at 0 °C, short term stability of ±0.01 °C and fast respond time of 5 seconds. These industrial PRTs come with standard length 12-inch but customized dimensions are available per request.  

To reach the best performance in stability and repeatability, the wire-wound sensing elements are specially designed to protect the platinum sensing wire from contamination at high temperature. A unique support structure and filling material provide the best balance among the hysteresis effect, mechanical shock and thermal shock performance. All of these probes conform to the standard 385 curve so the resistance ratio of the PRT follow DIN/IEC-751 curve precisely.

Specifications

 

Temperature Range

1660: -200 °C to 670 °C                       

1640: -200 °C to 420 °C                       

1620: -60 °C to 300 °C

Resistance at 0 °C

Nominal 100 Ω

Temperature Coefficient

0.00385 Ω/ Ω/°C

Accuracy

±0.04 °C at -200 °C

±0.035 °C at 0°C

±0.05 °C at 200 °C

±0.09 °C at 420 °C

±0.15 °C at 660 °C

Drift

±0.04 °C at 0 °C after 100 hours at 420 °C

Short Term Stability

±0.01 °C

Thermal Shock

±0.007 °C after 10 times thermal cycles from minimum to maximum temperatures

Hysteresis

<=0.01 °C

Self-heating

50 mW/°C

Response Time

5 seconds for 63% response to step change in water moving at 3 feet per second

Measurement Current

0.5 mA or 1 mA

Sensor Length

32 mm

Sensor Location

5 mm from tip

Insulation Resistance

>1000 MΩ at room temperature

Sheath Material

1660/1640: Inconeltm

1620: 316 Stainless Steel

Dimension

0.25 inch X 12 inch (6.35 mm X 305 mm)

External Leads

Teflontm –insulated copper wire, 4 leads, 2.5 meters

Handle Dimension

15mm (OD) X 65 mm (L)

Handle Temperature Range*

-50 °C to 180 °C

Optional Calibration

NIST traceable calibration and data available per request:

1660-12: Ordering # 5007

1640-12: Ordering # 5014

1620-12: Ordering # 5015

Optional Accessories

 

Model

Description

9001

Wooden Carrying Case

 

Image Gallery

 

 

 

 

 

AccuMac AM1710  Secondary Reference PRT

AccuMac AM1710 Secondary Reference PRT

AccuMac AM1710 - Secondary Reference PRT

  

  • Temperature range: -60 °C to 160 °C
  • Accuracy: ±0.015 °C
  • Long term drift: ±0.01 °C
  • Short term stability: 0.007 °C
  • Durable and shock resistance
  • Temperature Coefficient 0.003925
  • W(Ga)>=1.11807
  • Stainless steel sheath
  • Customized dimensions available

 

Overview

AM1710 series Secondary Reference PRT provides our customers an affordable reference probe for precision temperature measurement and calibration in labs and fields. The PRT features accuracy of ±0.015°C, short term stability of ±0.007°C.  Two different lengths of PRTs are available at 9-inch and 12-inch.  

To reach the best performance in stability and repeatability, the sensing element is specially designed to protect the platinum sensing wire from contamination at high temperature. A unique support structure and filling material provide the best balance among the hysteresis effect, mechanical shock and thermal shock performance. This high performance probe meets ITS-90 criteria of reference thermometer fully.

Specifications

 

Temperature Range

-60 °C to 160 °C

Resistance at 0 °C

Nominal 100 Ω

Temperature Coefficient

0.003925 Ω/ Ω/°C

Accuracy

±0.015 °C at 0.01 °C

Drift

±0.01 °C at TPW after 100 hours at 160 °C

Short Term Stability

±0.007 °C

Thermal Shock

±0.005 °C after 10 times thermal cycles from minimum to maximum temperatures

Hysteresis

<=0.005 °C

Self-heating

50 mW/°C

Response Time

9 seconds for 63% response to step change in water moving at 3 feet per second

Measurement Current

0.5 mA or 1 mA

Sensor Length

32 mm

Sensor Location

5 mm from tip

Insulation Resistance

>1000 MΩ at room temperature

Sheath Material

Stainless Steel

Dimension

0.25 inch X 12 inch (6.35 mm X 305 mm)

External Leads

Teflontm –insulated copper wire, 4 leads, 2.5 meters

Handle Dimension

1710-12: 15 mm (OD) x 65 mm (L)

1710-9: 10 mm (OD) X 50 mm (L)

Handle Temperature Range*

-50 °C to 160 °C

Optional Calibration

NIST traceable calibration and data available per request:

Ordering # 5017

 

Optional Accessories

 

Model

Description

9001

Wooden Carrying Case

Image Gallery

 

 

 

 

 

AccuMac AM1730  Secondary Reference PRT

AccuMac AM1730 Secondary Reference PRT

AccuMac AM1730 - Secondary Reference PRT

  

  • Temperature range: -200 °C to 420 °C
  • Accuracy: ±0.015 °C
  • Long term drift: ±0.01 °C
  • Short term stability: 0.007 °C
  • Durable and shock resistance
  • Temperature Coefficient 0.003925
  • W(Ga)>=1.11807
  • Inconel sheath
  • Customized dimensions available

 

Overview

AM1730 series Secondary Reference PRT provides our customers an affordable reference probe for precision temperature measurement and calibration in labs and fields. The PRT features accuracy of ±0.015°C, short term stability of ±0.007°C.  Two different lengths of PRTs are available at 9-inch and 12-inch.  

To reach the best performance in stability and repeatability, the sensing element is specially designed to protect the platinum sensing wire from contamination at high temperature. A unique support structure and filling material provide the best balance among the hysteresis effect, mechanical shock and thermal shock performance. This high performance probe meets ITS-90 criteria of reference thermometer fully.

 

Specifications

 

Temperature Range

1730-12: -200 °C to 420 °C

1730-9: -60 °C to 300 °C

Resistance at 0 °C

Nominal 100 Ω

Temperature Coefficient

0.003925 Ω/ Ω/°C

Accuracy

±0.025 °C at -196 °C

±0.015 °C at 0.01 °C

±0.035 °C at 420 °C

Drift

±0.01 °C at TPW after 100 hours at 420 °C

Short Term Stability

±0.007 °C

Thermal Shock

±0.005 °C after 10 times thermal cycles from minimum to maximum temperatures

Hysteresis

<=0.005 °C

Self-heating

50 mW/°C

Response Time

9 seconds for 63% response to step change in water moving at 3 feet per second

Measurement Current

0.5 mA or 1 mA

Sensor Length

32 mm

Sensor Location

5 mm from tip

Insulation Resistance

>1000 MΩ at room temperature

Sheath Material

Inconeltm

Dimension

 1730-12: 0.25 inch X 12 inch (6.35 mm X 305 mm)

1730-9: 0.187 inch X 9 inch (4.75 mm X 229 mm)

External Leads

Teflontm –insulated copper wire, 4 leads, 2.5 meters

Handle Dimension

1730-12: 15 mm (OD) x 65 mm (L)

1730-9: 10 mm (OD) X 50 mm (L)

Handle Temperature Range*

-50 °C to 180 °C

Optional Calibration

NIST traceable calibration and data available per request:

1730-12: Ordering # 5014

1730-9: Ordering # 5015

 

Optional Accessories

 

Model

Description

9001

Wooden Carrying Case

 

Image Gallery

 

 

 

 

 

AccuMac AM1751  Secondary Reference PRT

AccuMac AM1751 Secondary Reference PRT

AccuMac AM1751 - Secondary Reference PRT

  

  • Temperature range: -200 °C to 670 °C
  • Accuracy: ±0.015 °C at 0.01°C
  • Long term drift: ±0.01 °C
  • Short term stability: 0.007 °C
  • Durable and shock resistance
  • Temperature Coefficient 0.003925
  • W(Ga)>=1.11807
  • Inconel sheath
  • Customized dimensions available

Overview

AM1751 series Secondary Reference PRT provides our customers an affordable reference probe for precision temperature measurement and calibration in labs and fields. The PRT features accuracy of ±0.015 °C at 0.01 °C ; short term stability of ±0.007 °C.  Two different lengths of PRTs are available at 12-inch and 20-inch.  

The sensing element is designed to protect the platinum sensing wire from contamination at high temperatures, giving the device a high level of stability and repeatability in performance. A uniquely designed support structure and filling material provides excellent balance between the hysteresis effect, mechanical shock and thermal shock performance. This high performance probe fully meets ITS-90 criteria for reference thermometers.

Specifications

 

Temperature Range

1751-12: -200 °C to 670 °C

1751-20: -200 °C to 670 °C

Resistance at 0 °C

Nominal 100 Ω

Temperature Coefficient

0.003925 Ω/ Ω/°C

Accuracy

±0.025 °C at -196 °C

±0.015 °C at 0.01 °C

±0.035 °C at 420 °C

±0.05 °C at 661 °C

Drift

±0.01 °C at TPW after 100 hours at 661 °C

Short Term Stability

±0.007 °C

Thermal Shock

±0.005 °C after 10 times thermal cycles from minimum to maximum temperatures

Hysteresis

<=0.005 °C

Self-heating

50 mW/°C

Response Time

9 seconds for 63% response to step change in water moving at 3 feet per second

Measurement Current

0.5 mA or 1 mA

Sensor Length

32 mm

Sensor Location

5 mm from tip

Insulation Resistance

>1000 MΩ at room temperature

Sheath Material

Inconeltm

Dimension

1751-12: 0.25 inch X 12 inch (6.35 mm X 305 mm)

1751-20: 0.25 inch X 20 inch (6.35 mm X 500 mm)

External Leads

Teflontm –insulated copper wire, 4 leads, 2.5 meters

Handle Dimension

15 mm (OD) X 65 mm (L)

Handle Temperature Range*

-50 °C to 180 °C

Optional Calibration

NIST traceable calibration and data available per request, Ordering # 5007

Optional Accessories

 

Model

Description

9001

Wooden Carrying Case for 1760/1751-12

9902

Wooden Carrying Case for 1760/1751-20

Image Gallery

 

 

 

 

 

AccuMac AM1758  Gradient PRT

AccuMac AM1758 Gradient PRT

AccuMac AM1758 - Gradient PRT

  

Vertical gradient measurement of dry block/dry well

6 mm sensing element

Temperature range: -200 °C to 670 °C

Short term stability: ±0.003 °C at 0.01°C

Overview

AM1758 is specifically designed to measure vertical gradients of dry blocks or dry wells. The length of the replica watches uk sensing element is only 6 mm, which allows AM1758 to measure detailed temperature changes inside the dry wells with pin point precision.

The short sensing element has adopted many of AccuMac’s PRT technologies to offer a high level of replica omega watches stability across the temperature range from -200 °C to 670 °C. A uniquely designed support structure and filling material provides excellent balance between the hysteresis effect, mechanical shock and thermal shock performance.

It has long been a challenge for temperature calibration labs across the world to measure gradient of a dry block. With a 6 mm sensing element, AM1758 meets challenge and requirement such as one from The Euramet Calibration Guide CG-13 Version 3.0 “CALIBRATION OF TEMPERATURE BLOCK CALIBRATORS”

 

Specifications

 

Temperature Range

From -200 °C to 670 °C

Resistance at 0 °C

Nominal 25 Ω

Temperature Coefficient

0.003925 Ω/ Ω/°C

Short Term Stability (1)

±0.003 °C at -196 °C

±0.003 °C at 0.01 °C

±0.004 °C at 232 °C

±0.005 °C at 420 °C

±0.006 °C at 661 °C

Hysteresis

<=0.005 °C

Self-heating

0.0015 °C at 1 mA current

Response Time

9 seconds for 63% response to step change in water moving at 3 feet per second

Measurement Current

1 mA

Sensor Length

6 mm

Sensor Location

3 mm from tip

Insulation Resistance

>1000 MΩ at room temperature

Sheath Material

Inconeltm

Dimension

0.25 inch X 12 inch (6.35 mm X 305 mm)

External Leads

Teflontm –insulated copper wire, 4 leads, 2.5 meters

Handle Dimension

15 mm (OD) X 65 mm (L)

Handle Temperature Range (2)

-50 °C to 180 °C

Optional Calibration

NIST traceable calibration and data available per request: Ordering # 5007

 

Optional Accessories

 

Model

Description

9001

Wooden Carrying Case

Image Gallery

 

 

 

 

 

AccuMac AM1760/1762  Secondary SPRTs

AccuMac AM1760/1762 Secondary SPRTs

AccuMac AM1760/1762 - Secondary SPRTs

  


  • Temperature range: -200 °C to 670 °C
  • Accuracy: ±0.006 °C at 0.01 °C
  • Long term drift: ±0.019 °C
  • Short term stability: 0.002 °C
  • Temperature Coefficient 0.003925
  • W(Ga)>=1.11807
  • Inconel sheath
  • Customized dimensions available

Overview

AM1760 series Secondary Standard PRT provides our customers reliable secondary standards that can be used daily in their labs. This SPRT features accuracy of ±0.006 °C at 0.01 °C , short term stability of ±0.002°C and very low drift rate of less than 4 mK after 100 hours at 661 °C. Two different lengths of SPRTs are available at 12-inch and 20-inch.   

The sensing element is designed to protect the platinum sensing wire from contamination at high temperatures, giving the device a high level of stability and repeatability in performance. A uniquely designed support structure and filling material provides excellent balance between the hysteresis effect, mechanical shock and thermal shock performance. This high-performance probe fully meets ITS-90 criteria for reference thermometers.

Specifications

 

Temperature Range

-200 °C to 670 °C

Resistance at 0 °C

1760 – Nominal 100 Ω

1762 – Nominal 25 Ω

Temperature Coefficient

0.003925 Ω/ Ω/°C

Accuracy

±0.007 °C at -196 °C

±0.006 °C at 0.01 °C

±0.015 °C at 420 °C

±0.025 °C at 661 °C

Drift*

±0.004 °C at TPW after 100 hours at 661 °C

Short Term Stability

±0.002 °C

Thermal Shock

±0.002 °C after 10 times thermal cycles from minimum to maximum temperatures

Self-heating

0.0015 °C at 1 mA current

Response Time

9 seconds for 63% response to step change in water moving at 3 feet per second

Measurement Current

0.5 mA or 1 mA

Sensor Length

42 mm

Sensor Location

5 mm from tip

Insulation Resistance

>1000 MΩ at room temperature

Sheath Material

Inconeltm

Dimension

1760/1762-12: 0.25 inch X 12 inch (6.35 mm X 305 mm)

1760/1762-20: 0.25 inch X 20 inch (6.35 mm X 500 mm)

External Leads

Teflontm –insulated copper wire, 4 leads, 2.5 meters

Handle Dimension

15 mm (OD) X 65 mm (L)

Handle Temperature Range**

-50 °C to 180 °C

Optional Calibration

NIST traceable calibration and data available per request: Ordering # 5007

Optional Accessories

 

Model

Description

9001

Wooden Carrying Case for 1760/1762-12 included

9902

Wooden Carrying Case for 1760/1762-20 included

 

Image Gallery

 

 

 

 

 

AccuMac AM1860/1850  Metal SPRTs

AccuMac AM1860/1850 Metal SPRTs

AccuMac AM1860/1850 - Metal SPRTs

  

Metal sheathed

Great reference thermometer for dry block calibrators

Temperature range: -200 °C to 670 °C

 

Overview

Standard Platinum Resistance Thermometers (SPRTs) are common used to interpolate temperature in the range from -189.3442°C to 660.323°C on the International Temperature Scale of 1990 (ITS-90).  They are widely used as standard or reference thermometers to calibrate other thermometers and to measure temperature precisely in primary and secondary laboratories. AM1850 and AM1860 SPRTs are the crown jewels of AccuMac temperature probes. It takes decades of our scientific expertise and original breitling copy watches craftsmanship to create these world class products. They feature a very low drift rate.

To improve the durability of the SPRT, Inconel 600 replaces quartz glass as sheath material of the thermometer. A special capsule is adopted to protect the platinum sensor wire from contamination introduced by metal sheath at high temperature. All parts used in the thermometer are completely cleaned and treated at high temperature before assembly. The gas mixture filled in the thermometer is well controlled to reduce oxidation effect as low as possible. Every SPRT is fully tested for stability after manufactured. This world class probe meets ITS-90 criteria of standard thermometer fully with a very competitive pricing.

AM1850 has a temperature range from -200°C to 500°C. AM1860 covers range from -200°C to 670°C. They are widely used as reference thermometer at drywell block calibrator and temperature bath.

 

Specifications

 

Temperature Range

1850: -200 °C to 500 °C

1860: -200 °C to 670 °C

Rtpw

Nominal 25 Ω or nominal 100 Ω

Resistance Ratio

W(Ga)>=1.11807

W(Hg)<=0.844235

Drift at 0.01 °C*

1850     <0.002 °C after 100 hours at 500 °C

             <0.008 °C/year typical

1860     <0.003 °C after 100 hours at 661 °C

             <0.01 °C/year typical

Repeatability

±0.0015 °C

Thermal Shock

±0.0015 °C after 10 times thermal cycles from minimum to maximum temperatures

Self-heating

0.0015 °C at 1 mA current

Measurement Current

1 mA

Sensor Length

42 mm

Insulation Resistance

>1000 MΩ at room temperature

Sheath Material

InconelTM

Dimension

1850: 6.35 mm (OD) X 480 mm (L)

1860: 6.35 mm (OD) X 500 mm (L)

External Leads

Insulated copper wire, 4 leads, 2.5 meters

Termination

Gold-plated Spade

Handle Dimension

21 mm (OD) X 80 mm (L)

Optional Calibration

NVLAP/ISO17025 accredited calibration and data available per request

 

Optional Accessories

 

Model

Description

9002

Wooden Carrying Case included

 

Image Gallery

 

 

 

 

 

AccuMac AM1880  Metal-Sheath SPRT

AccuMac AM1880 Metal-Sheath SPRT

AccuMac AM1880 - Metal-Sheath SPRT

  

Bird-Cage design to make it mechanical shocks resistant

Platinum Capsule to protect sensor from high temperature contaminations

Metal Sheath for harsh environment

Temperature range: -200 °C to 670 °C

5.56mm diameter for quick responses

 Overview

AM1880 Standard Platinum Resistance Thermometers (SPRT) interpolates temperature in the range from -200 °C to 670 °C on the International Temperature Scale of 1990 (ITS-90). It is designed as a primary or secondary standard thermometer to calibrate other thermometers and/or to measure temperature precisely in primary and secondary laboratories.

The sensing element and sensor support adopt a “Bird-Cage” design and they are protected inside a platinum capsule. Compared to the traditional coil wounding method, the “Bird-Cage” handles mechanical shocks much better at the same time allows for high purity platinum wire to be wound strain-free. The platinum capsule protects the sensing element from contamination at high temperature. The “Bird-Cage” structure combined with 5.56 mm Inconel sheath makes this SPRT responds to temperature changes much faster. All parts used in the SPRT are thoroughly cleaned before assembly and the assembly process is well controlled to protect the sensor from contaminations. The gas mixture filled in the thermometer makes the sensor wire oxidation effect as low as possible.

Every AM1880 SPRT is fully tested for stability after manufactured. This world class probe meets ITS-90 criteria of standard thermometer fully.

 

Specifications

 

Temperature Range

-200 °C to 670 °C

Rtpw

Nominal 25.5 Ω

Resistance Ratio

W(Ga)>=1.11807

W(Hg)<=0.844235

Drift at 0.01 °C*

<0.006 °C/year, <0.003 °C/year typical

Repeatability

<0.001 °C

Thermal Shock

<0.001 °C after 10 times thermal cycles from minimum to maximum temperatures

Self-heating

<0.0015 °C at 1 mA current

Measurement Current

1 mA

Sensor Length

42 mm

Insulation Resistance

>1000 MΩ at room temperature

Sheath Material

Inconel

Dimension

5.56 mm (OD) X 500 mm (L)

External Leads

Insulated copper wire, 4 leads, 2.5 meters

Termination

Gold-plated Spade

Handle Dimension

21 mm (OD) X 80 mm (L)

Optional Calibration

NVLAP/ISO17025 accredited calibration and data available per request

Optional Accessories

 

Model

Description

9002

Wooden Carrying Case included

 

Image Gallery

 

 

 

 

 

AccuMac AM1960/1950  Quartz SPRTs

AccuMac AM1960/1950 Quartz SPRTs

AccuMac AM1960/1950 - Quartz SPRTs

  

Affordable primary standards

Extremely low drift rate

Temperature range: -200 °C to 670 °C

 

Overview

Standard Platinum Resistance Thermometers (SPRTs) are used to interpolate temperature in the range from -189.3442 °C to 660.323 °C on the International Temperature Scale of 1990 (ITS-90).  They are widely used as standard or reference thermometers to calibrate other thermometers and to measure temperature precisely in primary and secondary laboratories. AM1950 and AM1960 SPRTs are the crown jewels of AccuMac temperature probes. It takes decades of our scientific expertise and original craftsmanship to create these world class products. They feature a very low drift rate.

To reach the best performance in stability and repeatability, the sensing element and sensor support are specially designed. To protect the platinum sensing wire from contamination at high temperature, all parts used in the thermometer are extremely cleaned before assembly. The assembly process is well controlled to protect the sensor from contamination. The gas mixture filled in the thermometer makes the sensor wire oxidation effect as low as possible. Every SPRT is fully tested for stability after manufactured. This world class probe meets ITS-90 criteria of standard thermometer fully with a very competitive pricing.

AM1950 has a temperature range from -200 °C to 500 °C. AM1960 covers range from -200 °C to 670 °C.

 

Specifications

 

Temperature Range

1950: -200 °C to 500 °C

1960: -200 °C to 670 °C

Rtpw

Nominal 25 Ω

Resistance Ratio

W(Ga)>=1.11807

W(Hg)<=0.844235

Drift at 0.01°C*

1950      <0.002 °C after 100 hours at 500 °C,

              <0.004 °C/year typical

1960      <0.003 °C after 100 hours at 661 °C,

              <0.005 °C/year typical

Repeatability

±0.001 °C

Thermal Shock

±0.001 °C after 10 times thermal cycles from minimum to maximum temperatures

Self-heating

0.0015 °C at 1 mA current

Measurement Current

1 mA

Sensor Length

42 mm

Insulation Resistance

>1000 MΩ at room temperature

Sheath Material

Quartz

Dimension

1950: 7 mm (OD) X 480 mm (L)

1960: 7 mm (OD) X 500 mm (L)

External Leads

Insulated copper wire, 4 leads, 2.5 meters

Termination

Gold-plated Spade

Handle Dimension

21 mm (OD) X 80 mm (L)

Optional Calibration

NVLAP/ISO17025 accredited calibration and data available per request

 

Optional Accessories

 

Model

Description

9002

Wooden Carrying Case included

 

Image Gallery

 

 

 

 

 

AccuMac AM1968  Capsule SPRT

AccuMac AM1968 Capsule SPRT

AccuMac AM1968 - Capsule SPRT

  

  • Temperature range: -260 °C to 100 °C
  • Long term drift: <0.003 °C at TPW after 1 year, <0.001 °C typical
  • Short term stability: 0.001 °C at 0.01 °C
  • Temperature Coefficient: 0.003925 Ω/Ω/°C
  • W(Ga) >= 1.11807
  • W(Hg) <= 0.844235
  • Platinum sheath

 

Overview

AM1968 Platinum Capsule SPRT covers temperatures from -260°C to 100 °C. The capsule construction makes this SPRT a preferred primary standard for cryogenic applications and other applications where space is limited or stem conduction is a concern for a long stem SPRT.

The sensing element is made of pure platinum wires with a temperature coefficient of 0.003925 Ω/Ω/°C. The coiled platinum wires are mounted in a way that is strain free and enclosed in a platinum capsule, which is sealed by glass. The special sealing glass has a thermal expansion coefficient that matches with that of the platinum wire to ensure the capsule SPRT is sealed permanently in the entire temperature range. A uniquely designed support structure provides excellent performances of stability, mechanical shock, and thermal cycle performance. The SPRT achieves a high level of stability and repeatability in performance and fully meets ITS-90 criteria for reference thermometers.

 

Specifications

 

Temperature Range

-260 °C to 100 °C

Resistance at 0.01 °C

Nominal 25 Ω

Temperature Coefficient

0.003925 Ω/ Ω/°C

Drift at 0.01 °C*

< 0.003 °C after 1 year, < 0.001 °C typical

Short Term Stability

±0.001 °C

Thermal Shock

±0.001 °C after thermal cycles from minimum to maximum temperatures

Self-heating

0.0015 °C at 1 mA current

Resistance Ratios

W(Ga)>=1.11807, W(Hg)<=0.844235

Measurement Current

1 mA

Sensor Length

42 mm Replica Watches uk

Filling Gas

Helium

Sheath Material

Platinum

Dimension

Sheath diameter 5mm, glass head diameter 7.5mm, length 60mm

External Leads

4 platinum wires, 30mm

 

Optional Accessories

 

Model

Description

9007

Wooden Carrying Case included

 

Image Gallery

 

 

 

 

 

AccuMac AM8010  Handheld Thermometer

AccuMac AM8010 Handheld Thermometer

AccuMac AM8010 - Handheld Thermometer

  

  • High accuracy: ±0.03 °C at 0 °C
  • High resolution: 0.01 °C
  • Temperature range: -200 °C to 850 °C
  • Work with PRTs with α=0.00385 and α=0.003925
  • ITS-90, CVD, IEC-751
  • 2.7- inch LCD display
  • Full-size Touchpad for function control
  • Temperature can be displayed in °C, °F or ohm.
  • Flexible interface with user key-in coefficients
  • USB interface for real time data saving and displaying on PC
  • Dual power supply with batteries or external power adaptor/computer USB interface

 

Overview

AM8010 is a handheld digital thermometer with high accuracy, fast readings and great stability. This readout is perfect for field applications as well as lab measurement. Though small in size, AM8010 is powerful when it comes to accuracy, which can be as high as 0.01 °C at 0 °C. A USB interface allows user to log and display real time data on a PC.

AM8010 digital thermometer allows users to choose ITS-90, IEC-751 (DIN), or Callendar-Van Dusen conversion methods to response various PRTs. All probe constants and coefficients can be keyed in replica breitling watches through front panel.

This portable readout is a powerful device with relative small price. 

 

 Specifications

 

Temperature Range

-200 °C to 850 °C, depending on PRT used

Accuracy (meter only)

±0.0 4°C at -200 °C

±0.03 °C at 0 °C

±0.04 °C at 232 °C

±0.05 °C at 420 °C

±0.06 °C at 660 °C

±0.07 °C at 850 °C

Resolution

0.01 °C (0.001 Ω) over full range

Stability

±0.01 °C 

Probe

100 Ω RTD, PRT or SPRT

Characterizations

ITS-90 coefficients, Callender Van Dusen coefficients, IEC-751 (DIN 385)

Sample Interval

1 second

Display

2.7 inch LCD

Display Units

°C, °F, Ω

Excitation Current

1 mA, reversing

Operation Range

15 °C to 35 °C

Thermometer Input Connectors

5-pin plug

Power Requirements

100-240 V

Battery Life

90 hours

Dimension

141 mm (L) X 25 mm (H) X 89 mm (W)

Weight

0.2 kg (0.5 lbs)

 

Optional Accessories

 

Model

Description

1610-12/9/6

Precision Industrial PRT, -60 °C to 160 °C

1620-12/9/6

Precision industrial PRT, -60 °C to 300 °C

1640-12

Precision industrial PRT, -200 °C to 420 °C

1660-12

Precision industrial PRT, -200 °C to 670 °C

1730-12

Secondary Reference PRT, -200 °C to 420 °C

1750-12/20

Secondary Reference PRT, -200 °C to 670 °C

 

Image Gallery

 

 

 

 

 

AccuMac AM8040  Precision Thermometer

AccuMac AM8040 Precision Thermometer

AccuMac AM8040-Precision Thermometer

   

  • High accuracy: up to ±0.008 °C at 0 °C
  • High resolution: 0.001 °C
  • Temperature range: -200 °C to 850 °C
  • ITS-90, CVD, IEC-751 conversion methods or key in coefficients of PRTs
  • 2.7- inch LCD display
  • Full-size Touchpad for function control
  • Data storage into USB flash disk
  • Data transfer to PC using an USB cable
  • Wireless data transfer to PC with an optional wireless module

 

Overview

AM8040 Precision Thermometer provides the best values with high standard performance. It features high accuracy, fast readings and great stability. It operates with a wide range of Platinum Resistance Thermometers (PRTs). All of the readings can be stored in a USB flash disk or transferred to PC through an USB cable or a wireless module.

AM8040 Precision Thermometer allows users to choose ITS-90, IEC-751 (DIN), or Callendar-Van Dusen conversion methods to response to various PRTs. Users can also choose to key in calibration data of each PRT to ensure the best accuracy.

AM8040 is the solution for precision temperature measurement and calibration at a very attractive price.

 

Specifications

 

Temperature Range

-200°C to 850°C, depending on PRT used

Accuracy 

±0.01°C @ -200°C

±0.008°C @ 0°C

±0.009°C @ 232°C

±0.01°C @ 420°C

±0.015°C @ 660°C

±0.025°C @ 850°C

Resolution

0.001°C (0.0001 Ω) over full range

Probe

Nominal Rtpw: 25 Ω or 100 Ω RTD, PRT or SPRT

Characterizations

ITS-90 coefficients, Callender Van Dusen coefficients, IEC-751 (DIN 385)

Sample Interval

1 second

Display

2.7 inch LCD

Display Units

°C, °F, Ω

Excitation Current

1 mA, reversing

Operation Range

15 °C to 35 °C

Thermometer Input Connectors

Spade plug or bare wire

Power Requirements

100-220V

Dimension

180 mm (W) X 65 mm (H) X 200 mm (D)

Weight

0.3 kg (0.7 lbs)

 

 Optional Accessories

1620-12/9/6

Precision industrial PRT, -60°C to 300°C

1640-12

Precision industrial PRT, -200°C to420°C

1660-12

Precision industrial PRT, -200°C to 670°C

1730-12

Secondary Reference PRT, -200°C to 420°C

1750-12/20

Secondary Reference PRT, -200°C to 670°C

1850

Metal-sheath SPRT, -200°C to 500°C

1860

Metal-sheath SPRT, -200°C to 670°C

1950

Quartz-sheath SPRT, -200°C to 500 °C

1960

Quartz-sheath SPRT, -200°C to 670 °C

 

Image Gallery

 

 

 

 

 

AccuMac AM8060  2-ch Precision Thermometer

AccuMac AM8060 2-ch Precision Thermometer

AccuMac AM8060 2-ch Precision Thermometer

 

  • High accuracy: up to ±0.008 °C at 0 °C
  • High resolution: 0.001 °C
  • Temperature range: -200 °C to 850 °C
  • Two inputs for reading two different sensors simultaneously
  • Differential temperature measurement
  • ITS-90, CVD, IEC-751
  • 2.7- inch LCD display
  • Full-size Touchpad for function control
  • User key-in coefficients to ensure the best accuracy
  • Data storage into USB flash disk
  • Data transfer to PC using an USB cable
  • Wireless data transfer to PC with an optional wireless module

Overview

AM8060 Precision Thermometer provides high accuracy, fast readings and great stability. It comes with dual channel measurement of temperature with Platinum Resistance Thermometers (PRTs). The temperature of each input and their temperature difference are displayed simultaneously. All of the readings can be stored in a USB flash disk or transferred to PC through a wireless module or an USB cable.

AM8060 Precision Thermometer allows users to choose ITS-90, IEC-751 (DIN), or Callendar-Van Dusen conversion methods to response to various PRTs. Users can also choose to key in calibration data of each PRT to ensure the best accuracy.

This dual-channel readout is a great choice for precision temperature measurement and calibration. It’s also a top choice as temperature reference for Drywell Calibrators and Temperature Bath.

 

Specifications

 

Temperature Range

-200°C to 850°C, depending on PRT used

Accuracy (meter only)

±0.01°C @ -200°C

±0.008°C @ 0°C

±0.009°C @ 232°C

±0.01°C @ 420°C

±0.015°C @ 660°C

±0.025°C @ 850°C

Resolution

0.001°C (0.0001 Ω) over full range

Probe

Nominal Rtpw: 25 Ω or 100 Ω RTD, PRT or SPRT

Characterizations

ITS-90 coefficients, Callender Van Dusen coefficients, IEC-751 (DIN 385)

Sample Interval

1 second

Display

2.7 inch LCD

Display Units

°C, °F, Ω

Excitation Current

1 mA, reversing

Operation Range

15 °C to 35 °C

Thermometer Input Connectors

Spade plug or bare wire

Power Requirements

100-220V

Dimension

180 mm (W) X 65 mm (H) X 200 mm (D)

Weight

0.3 kg (0.7 lbs)

Optional Accessories

 

Model

Description

8000-WLM

Wireless module for AM-8040 and AM-8060 precision thermometer

1610-12/9/6

Precision Industrial PRT, -60°C to 160°C

1620-12/9/6

Precision industrial PRT, -60°C to 300°C

1640-12

Precision industrial PRT, -200°C to420°C

1660-12

Precision industrial PRT, -200°C to 670°C

1730-12

Secondary Reference PRT, -200°C to 420°C

1750-12/20

Secondary Reference PRT, -200°C to 670°C

1850

Metal-sheath SPRT, -200°C to 500°C

1860

Metal-sheath SPRT, -200°C to 670°C

1950

Quartz-sheath SPRT, -200°C to 500 °C

1960

Quartz-sheath SPRT, -200°C to 670 °C

 

Image Gallery

 

 

 

 

 

AccuMac Products

AccuMac Products

 

 

 

 

  • «
  • 1
  • »
Information
  • Home
  • Youtube
  • About us
  • Contact
  • Peta Situs
  • Download
  Customer Service
  •  0818 920 386
  •  0818 920 386
  •  0822 9908 5294
  Tentang Kami

© 2016 www.pttriwi.com

Top