TecnoSoft
Refine Search
Pirani Vacuum Logger
Pirani Vacuum Logger
Pressure recorder for peroxide hydrogen autoclaves, with high accuracy at extreme vacuum
Arguably the best data logger for hydrogen peroxide autoclaves (plasma) and for freeze-drying processes you can find today. It has two sensors combined, one for the extreme vacuum and for higher pressures, up to 1200 bar: this allows to obtain an incredible accuracy of ±0.0003 and a resolution of 0,0001 mbar. Managed with Windows software and USB interface (DiskInterface HS). Battery is user replaceable and the data logger is provided with an Accredia (NIST equivalent) traceable certificate on different points. |
Main features
|
The system
|
Specification
Dimensions |
73 h X 30 Ø (mm) - 31 Ø (mm) peek ring |
Weight |
160 g |
Materials |
Stainless steel AISI316L, PEEK |
Temperature range |
-60 °C ÷ +85 °C |
Standard calibration points |
0/25/50/75°C |
Extra calibration points |
Within the range -20 °C ÷ +85 °C |
Temperature resolution |
0,01 °C |
Temperature accuracy |
± 0,1 °C from 0 °C to +85 °C |
Pressure range |
0,001 mbar ÷ 1200 mbar absolute |
Standard calibration points |
0,01/0,02/0,05/0,1/0,2/0,5/1/2/5/10/50/100/300/500/1000 mbar absolute @ t. amb (25°C +/-10°C) |
Pressure resolution |
0.0001 mbar |
Pressure accuracy |
± 0,0005 (0,001 ÷ 0,005) / ± 0,0003 (0,005 ÷ 0,01) / ± 0,01 (0,01 ÷ 0,1) / ± 0,05 (0,1 ÷ 0,5) / ± 0,1 (0,5 ÷ 1) / ± 0,5 (1 ÷ 5) / ± 2 (5 ÷ 10) / ± 3 (100 ÷ 500) / ± 5 (500 ÷ 1000); all values in mba |
Memory (n. of acquisitions) |
43.690 |
Acquisition step |
From 1 every second up, with 1 second steps |
Battery life |
+19.000.000 acquisitions at 1 second step continuously (calculated time @25°C. Battery life may be shorter if used in low temperatures) |
Software & Mobile App |
HumiPressureDisk, TS Manager |
Accessories |
DiskInterface HS, |
Ordering codes
|
Pirani Vacuum Logger |
Accessories
- HumiPressureDisk
- TS Manager
- DiskInterface HS
Image gallery
|
|
Pirani Vacuum Logger with thread
Pirani Vacuum Logger with thread Pressure monitoring in extreme vacuum, with 1/2 Gass thread
Main features
The system
Specification
Ordering codes
|
||||||||||||||||||||||||||||||||||||||
Accessories
Image gallery
|
PressPDF-L
PressPDF-L USB temperature, humidity and pressure data logger with LCD and generation of PDF report. HACCP and EN12830 regulations complaint.
Main features
Specification
Ordering codes
|
||||||||||||||||||||||||||||||||||||||||||||||||
Accessories
Image gallery
|
PressureDisk 05
PressureDisk 05 Pressure data logger from 0 to 5 bar provided with an Accredia (NIST equivalent) traceable certificate. All software calculates lethality value (F0, PU, A0 etc.)
Main features
The system
Specification
Ordering codes
|
||||||||||||||||||||||||||||||||
Accessories
Image gallery
|
PressureDisk Temperature and Pressure Data Logger
PressureDisk Temperature and pressure data-logger from -40°C to 140°C and from 0 to 5 bar. Provided with an Accredia traceable certificate
Main features
The system
Specification
Ordering codes
|
||||||||||||||||||||||||||||||||||||||||||||
Accessories
Image gallery
|
RHTemp125 L Humidity Temperature Data Logger
RHTemp125 L
Temperature and humidity data logger from -40°C to 125°C with USB interface
RHTemp125 L is a temperature and humidity data logger from -40°C to 125°C (calibration from 25°C to 125°C), managed with Windows software and USB interface (DiskInterface HS, Multibay). Battery is user replaceable and the data logger is provided with an Accredia (NIST equivalent) traceable cetificate on different points. |
Main features
|
The system
|
Specification
Dimensions |
46 h X 17 Ø mm - 18 Ø (mm) peek ring |
Weight |
36 g |
Materials |
Stainless steel AISI316L, PEEK |
Temperature range |
-40°C ÷ +125°C |
Standard calibration points |
23/50°C |
Extra calibration points |
Within the range -40 °C ÷ +125 °C |
Temperature resolution |
0,015 °C |
Temperature accuracy |
± 0,2 °C (0 °C ÷ +60 °C) / ± 1,3 °C (-20 °C ÷ +80 °C) / ± 2,3 °C (-20 °C ÷ +125 °C) derates linearly |
Humidity range |
0% ÷ 90% RH (non-condensing) |
Standard calibration points |
30/50/70% @ 23°C |
Extra calibration points |
Within the range 10% ÷ 90% RH |
Humidity resolution |
0,02% |
Humidity accuracy |
± 1,8% RH (10% ÷ 80%) / ± 4% RH (80% ÷ 90%) @ 23°C ± 10°C |
Memory (n. of acquisitions) |
10.112 |
Acquisition step |
From 1 every second up, with 1 second steps |
Protection degree |
IP50 |
Battery life |
+8.000.000 acquisitions at 1 second step continuously (calculated time @25°C. Battery life may be shorter if used in low temperatures) |
Software & Mobile App |
HumiPressureDisk, TS Manager |
Accessories |
DiskInterface HS, Universal Multibay |
Ordering codes TS17RHT125 RHTEMP125
Accessories
|
Image gallery
|
|
RHTemp125 XL Humidity- Temperature Data Logger
RHTemp125 XL
Temperature and humidity data logger from -40°C to 125°C. Completely food grade. It is provided with an Accredia (NIST equivalent) traceable certificate.
RHTemp125 XL is a temperature and humidity data logger from -40°C to 125°C (calibration from 25°C to 125°C), managed with Windows software and USB interface (DiskInterface HS, Multibay). Battery is user replaceable and the data logger is provided with an Accredia (NIST equivalent) traceable certificate on different points. |
Main features
|
The system
|
Specification
Dimensions |
71 h X 17 Ø (mm) - 18 Ø (mm) peek ring |
Weight |
57 g |
Materials |
Stainless steel AISI316L, PEEK |
Temperature range |
-40°C ÷ +125°C |
Standard calibration points |
23/50°C |
Extra calibration points |
Within the range -40 °C ÷ +125 °C |
Temperature resolution |
0,015 °C |
Temperature accuracy |
± 0,2 °C (0 °C ÷ +60 °C) / ± 1,3 °C (-20 °C ÷ +80 °C) / ± 2,3 °C (-20 °C ÷ +125 °C) derates linearly |
Humidity range |
0% ÷ 90% RH (non-condensing) |
Standard calibration points |
30/50/70% @ 23°C |
Extra calibration points |
Within the range 10% ÷ 90% RH |
Humidity resolution |
0,02% |
Humidity accuracy |
± 1,8% RH (10% ÷ 80%) / ± 4% RH (80% ÷ 90%) @ 23°C ± 10°C |
Memory (n. of acquisitions) |
10.112 |
Acquisition step |
From 1 every second up, with 1 second steps |
Protection degree |
IP50 |
Battery life |
+14.000.000 acquisitions at 1 second step continuously (calculated time @25°C. Battery life may be shorter if used in low temperatures) |
Software & Mobile App |
HumiPressureDisk, TS Manager |
Accessories |
DiskInterface HS, Universal Multibay |
Ordering codes
TS17RHT125 XL RHTEMP125 XL
Accessories
- HumiPressureDisk
- TS Manager
- DiskInterface HS
- Universal multibay
- Battery kit for RHTemp80 L and RHTemp125 L
Image gallery
|
|
RHTemp80 L Humidity Temperature Data Logger
RHTemp80 L Temperature and humidity data logger. Ideal for drying processes monitoring, especially of pasta, of powders and grains storehouses, of extreme environments.
Main features
The system
Specification
|
||||||||||||||||||||||||||||||||||||||||||
Ordering codes
Accessories
Image gallery
|
RHTemp80 XL Humidity and Temperature Data Logger
RHTemp80 XL Temperature and humidity data logger. Completely food grade. Accredia (NIST equivalent) traceable calibration certificate included.
Main features
The system
Specification
|
||||||||||||||||||||||||||||||||||||||||||
Ordering codes
Accessories
Image gallery
|
S-Micro Temperature data logger up to 220°C with probe of various lengths
S-Micro
Temperature data logger up to 220°C with probe of various lengths
Temperature data logger from 0°C to 220°C (standard calibration from 25°C to 140°C, climbable from 0°C to 220°C, only the probe above 140°C) with different lengths external probe (probes cannot be switched) on a 5 mm base (base height is not counted for probe length), managed with Windows software and USB interface: DiskInterface HS Mini (for P-Micro and S-Micro only, not for L and XL versions), DiskInterface HS and Multibay. With every S-Micro a battery kit for battery replacement is included. Battery is user replaceable and the data logger is provided with an Accredia (NIST equivalent) traceable certificate on 6 points. It is supported by the TS Manager software for validation compatible with the FDA 21 CFR Part 11 and GAMP 5 regulations. Note: when device is calibrated above 140°C accuracy and resolution might be less than what declared. |
Main features
|
The system
|
Specification
Dimensions |
14 h X 17 Ø (mm) |
Probes Dimensions |
Probe base dimensions 3 h X 14 Ø (mm) - Probe 20/50/100/150/on demand l X 3 Ø (mm) (l on demand: min. 12 mm / max. 175 mm. For longer probes ask for quotation) |
Weight |
13 g |
Materials |
Stainless steel AISI316L, PEEK |
Temperature range |
0 °C ÷ +140 °C |
Sensor temperature range |
0 °C ÷ +220 °C |
Standard calibration points |
25/50/75/100/121/140°C |
Extra calibration points |
Within the range 0 °C ÷ +220 °C |
Extra calibration points |
Up to 220°C (using the heat protections) |
Temperature resolution |
0,01 °C |
Temperature accuracy |
± 0,1 °C (within the calibration range) |
Memory (n. of acquisitions) |
20.224 |
Acquisition step |
From 1 every second up, with 1 second steps |
Protection degree |
IP68 |
Battery life |
560.000 acquisitions at 1 second step continuously (calculated time @25°C. Battery life may be shorter if used in low temperatures) |
Software & Mobile App |
SPD, TS Manager |
Accessories |
DiskInterface HS, Universal Multibay |
Ordering codes
TS01SM1 |
S-MICRO 20 |
TS01SM4 |
S-MICRO 50 |
TS01SM3 |
S-MICRO 100 |
TS01SM5 |
S-MICRO 150 |
TS01SMD |
S-MICRO ON DEMAND |
Accessories
- SPD
- TS Manager
- DiskInterface HS
- Universal multibay
- Fixing base
- Adhesive rubber for high temperatures
- Locking bolt
- Fastening system
- Teflon protective tube
- S-Micro heat protection 1
- S-Micro heat protection 2
- Battery kit for P-Micro, S-Micro
- Universal tool for opening logger
Image gallery
|
|
S-Micro L Temperature data logger up to 140°C with probe of various lengths
S-Micro L
Temperature data logger up to 140°C with probe of various lengths
S-Micro L is a temperature data logger from -40°C to 220°C (standard calibration from 25°C to 140°C, calibrable from 0°C to 220°C, only the probe will resist above 140°C) with 20 or 50 or 100 or 150 mm or on demand length external probe (probes cannot be switched) on a 5 mm base (base height is not counted for probe length), managed with Windows software and USB connecting bay: DiskInterface HS, Multibay. Battery is user replaceable and the data logger is provided with an Accredia (NIST equivalent) traceable cetificate on 6 points. It is supported by the TS Manager software for validation compatible with the FDA 21 CFR Part 11 and GAMP 5 regulations. Note: if used below -30°C, battery life will be highly reduced. When device is calibrated above 140°C accuracy and resolution might be less than what declared. |
Main features
- Reduced size: 17 mm diameter only
- With different lengths rigid probe for penetration
- Completely food grade and waterproof
- All software calculates lethality value (F0, PU, A0 etc.)
- Low battery consumption for an extended battery life
- User replaceable battery (software shows battery status)
- Very easy to deploy in any type of package
- Accredia (NIST equivalent) traceable calibration certificate included
- Available extended calibration from -40°C to 220°C (order extra calibration points; in case of wide calibration range the accuracy might be worse)
The system
- S-Micro L temperature data logger
- DiskInterface HS or Universal Multibay
- SPD software or TS Manager software (compatible with the FDA 21 CFR Part 11 regulation)
Specification
Dimensions |
39 h X 17 Ø (mm) |
Probes Dimensions |
Probe base dimensions 3 h X 14 Ø (mm) - Probe 20/50/100/150/on demand l X 3 Ø (mm) (l on demand: min. 12 mm / max. 175 mm. For longer probes ask for quotation) |
Weight |
36 g |
Materials |
Stainless steel AISI316L, PEEK |
Temperature range |
-40 °C ÷ +140 °C |
Sensor temperature range |
-40 °C ÷ +220 °C |
Standard calibration points |
25/50/75/100/121/140°C |
Extra calibration points |
Within the range 0 °C ÷ +220 °C |
Extra calibration points |
Up to 220°C (using the heat protections) |
Temperature resolution |
0,01 °C |
Temperature accuracy |
± 0,1 °C (within the calibration range) |
Memory (n. of acquisitions) |
20.224 |
Acquisition step |
From 1 every second up, with 1 second steps |
Protection degree |
IP68 |
Battery life |
+10.000.000 acquisitions at 1 second step continuously (calculated time @25°C. Battery life may be shorter if used in low temperatures) |
Software & Mobile App |
SPD, TS Manager |
Accessories |
DiskInterface HS, Universal Multibay |
Ordering codes
TS01SML1 |
S-MICRO L 20 |
TS01SML4 |
S-MICRO L 50 |
TS01SML3 |
S-MICRO L 100 |
TS01SML5 |
S-MICRO L 150 |
TS01SMLD |
S-MICRO L ON DEMAND |
Accessories
- SPD
- TS Manager
- DiskInterface HS
- Universal multibay
- Fixing base
- Adhesive rubber for high temperatures
- Locking bolt
- Fastening system
- Teflon protective tube
- S-Micro heat protection 1
- S-Micro heat protection 2
- Battery kit for P-Micro, S-Micro
- Universal tool for opening logger
Image gallery
|
|
S-Micro XL Temperature data logger up to 220°C with probe of various lengths
S-Micro XL
Temperature data logger up to 220°C with probe of various lengths
S-Micro XL is a temperature data logger from -40°C to 220°C (standard calibration from 25°C to 140°C, calibrable from 0°C to 220°C, only the probe will resist above 140°C) with 20 or 50 or 100 or 150 mm or on demand length external probe (probes cannot be switched) on a 5 mm base (base height is not counted for probe length), managed with Windows software and USB reading bay: DiskInterface HS, Multibay. Battery is user replaceable and the data logger is provided with an Accredia (NIST equivalent) traceable cetificate on 6 points. It is supported by the TS Manager software for validation compatible with the FDA 21 CFR Part 11 and GAMP 5 regulations. Note: if used below -30°C, battery life will be highly reduced. When device is calibrated above 140°C accuracy and resolution might be less than what declared. |
Main features
|
The system
|
Specification
Dimensions |
64 h X 17 Ø (mm) |
Probes Dimensions |
Probe base dimensions 3 h X 14 Ø (mm) - Probe 20/50/100/150/on demand l X 3 Ø (mm) (l on demand: min. 12 mm / max. 175 mm. For longer probes ask for quotation) |
Weight |
57 g |
Materials |
Stainless steel AISI316L, PEEK |
Temperature range |
-40 °C ÷ +140 °C |
Sensor temperature range |
-40 °C ÷ +220 °C |
Standard calibration points |
25/50/75/100/121/140°C |
Extra calibration points |
Within the range 0 °C ÷ +220 °C |
Extra calibration points |
Up to 220°C (using the heat protections) |
Temperature resolution |
0,01 °C |
Temperature accuracy |
± 0,1 °C (within the calibration range) |
Memory (n. of acquisitions) |
20.224 |
Acquisition step |
From 1 every second up, with 1 second steps |
Protection degree |
IP68 |
Battery life |
+17.000.000 acquisitions at 1 second step continuously (calculated time @25°C. Battery life may be shorter if used in low temperatures) |
Software & Mobile App |
SPD, TS Manager |
Accessories |
DiskInterface HS, Universal Multibay |
Ordering codes
TS01SMXL1 |
S-MICRO XL 20 |
TS01SMXL4 |
S-MICRO XL 50 |
TS01SMXL3 |
S-MICRO XL 100 |
TS01SMXL5 |
S-MICRO XL 150 |
TS01SMXLD |
S-MICRO XL ON DEMAND |
Accessories
- SPD
- TS Manager
- DiskInterface HS
- Universal multibay
- Fixing base
- Adhesive rubber for high temperatures
- Locking bolt
- Fastening system
- Teflon protective tube
- S-Micro heat protection 1
- S-Micro heat protection 2
- Battery kit for P-Micro, S-Micro
- Universal tool for opening logger
Image gallery
|
|
S-MicroW L Temperature data logger up to 250°C with probe
S-MicroW L Temperature data logger up to 250°C with probe of various lengths provided with an Accredia (NIST equivalent) traceable certificate
Main features
The system
Specification
Ordering codes |
||||||||||||||||||||||||||||||||||||||
Accessories
Image gallery
|
S-MicroW L Bendable 2mm
S-MicroW L Bendable 2mm Temperature data logger with bendable semi-rigid probe up to 250°C provided with Accredia traceable certificate
Main features
The system
Specification
Ordering codes |
||||||||||||||||||||||||||||||||||||||
Accessories
Image gallery
|
S-MicroW L Flexible Temperature autoclave data logger up to 140°C with flexible probe provided with
S-MicroW L Flexible Temperature autoclave data logger up to 140°C with flexible probe provided with an Accredia (NIST equivalent) traceable certificate
Main features
The system
Specification
Ordering codes
|
||||||||||||||||||||||||||||||||
Accessories
Image gallery
|
S-MicroW L Ultra Freeze
S-MicroW L Ultra Freeze Ultra-low temperature data logger from -80°C up to 140°C with probe of various lengths. It is particularly indicated for monitoring and validation of ultra-freezers.
Main features
The system
Specification
Ordering codes
|
||||||||||||||||||||||||||||||||||
Accessories
Image gallery
|
S-MicroW XL Temperature data logger up to 250°C with probe
S-MicroW XL
Temperature data logger up to 250°C with probe of various lengths ideal for food
S-MicroW XL is a temperature data logger from -40°C to 250°C (standard calibration from 25°C to 140°C, calibrable from 0°C to 250°C, only the probe will resist above 140°C. For calibrations above 140°C probe minimum length is 50 mm) with 20 or 50 or 100 or 150 mm or on demand length external probe (probes cannot be switched) on a 5 mm base (base height is not counted for probe length), managed with Windows software and USB interface (DiskInterface HS, Multibay). Battery is user replaceable and the data logger is provided with an Accredia (NIST equivalent) traceable cetificate on 6 points. |
Main features
|
The system
|
Specification
Dimensions |
64 h X 20 Ø (mm) |
Probes Dimensions |
Probe base dimensions 3 h X 14 Ø (mm) - Probe 20/50/100/150/on demand l X 3 Ø (mm) (l on demand: min. 12 mm / max. 175 mm. For longer probes ask for quotation) |
Weight |
61 g |
Materials |
Stainless steel AISI316L, PEEK |
Temperature range |
-40 °C ÷ +140 °C |
Sensor temperature range |
-40 °C ÷ +250 °C |
Standard calibration points |
25/50/75/100/121/140°C |
Extra calibration points |
Within the range -40°C ÷ +250°C |
Extra calibration points |
Up to 250°C (using the heat protections) |
Temperature resolution |
0,01 °C |
Temperature accuracy |
± 0,1 °C (within the calibration range) / ± 0,05 °C with ultra accuracy option |
Memory (n. of acquisitions) |
20.224 |
Acquisition step |
From 1 every second up, with 1 second steps |
Protection degree |
IP68 |
Battery life |
+17.000.000 acquisitions at 1 second step continuously (calculated time @25°C. Battery life may be shorter if used in low temperatures) |
Software & Mobile App |
SPD, TS Manager |
Accessories |
DiskInterface HS, Universal Multibay |
Ordering codes
Accessories
Image gallery
|
S-MicroW XL Bendable 2mm Temperature data logger up to 250°C
Main features
The system
Specification
|
||||||||||||||||||||||||||||||||||||||
Ordering codes
Accessories
Image gallery
|
S-MicroW XL Flexible Temperature data logger up to 140°C with flexible probe
S-MicroW XL Flexible
Temperature data logger up to 140°C with flexible probe
S-MicroW L Flexible is a temperature data logger from -40°C to 140°C (calibration from 25°C to 140°C) with 30 cm felxible probe and 50 mm or on demand length external probe (probes cannot be switched) on a 5 mm base (base height is not counted for probe length), managed with Windows software and USB interface (DiskInterface HS, Multibay). Battery is user replaceable and the data logger is provided with an Accredia (NIST equivalent) traceable cetificate on 6 points. |
Main features
|
The system
Specification
Ordering codes |
TS18SMWLF2 |
S-MICROW L FLEXIBLE 50 |
TS18SMWLFD |
S-MICROW L FLEXIBLE ON DEMAND |
Accessories
- SPD
- TS Manager
- Tecno Calib
- DiskInterface HS
- Universal multibay
- Locking bolt
- Fastening system
- Teflon protective tube
- S-MicroW L battery kit
Image gallery
|
|
S-MicroW XL Ultra Freeze
S-MicroW XL Ultra Freeze Ultra-low temperature data logger from -80°C up to 140°C with probe of various lengths. It is particularly indicated for monitoring and validation of ultra-freezers.
Main features
Specification
Ordering codes
|
||||||||||||||||||||||||||||||||||
Accessories
Image gallery
|